Page 7.6 - 20
COMBIVERT F5-A, -E, -H
© KEB, 2012-10
Motor data and controller adjustments of the synchronous motor
7.6.3.8
Functions in the SCL software
nn.00: Motor model select
Bit
Meaning
14
HF injektion
In order that these functions can be used, the following special requirements apply to the synchronous motor:
- The difference between Ld and Lq (minimum and maximum value ) should be greater than 30%.
- The curve of inductance with a circulation of rho should be sinusoidal.
These criteria can be checked during the identification (dr.48 = 2) by recording dr.31 and EC.40.
dS.30 rotor position detection
0 = off
dS.31 rotor position mode
0 : Ld different Lq
1 : Ld = Lq
The more favorable operating mode is preset by the motor identification and Fr10.
dS.32 KI HF detection
Illustration of nn.16 in dS parameters
This parameter is used to optimize the first operating mode dS.31 = 0
dS.33 current limit for HF supply
This parameter is preset by Fr10 after a motor identification.
The voltage jump is adjusted by way that the preset current is approximately reached.
This parameter must be increased if the rotor position at dS.31 = 1 is suboptimal.
The current is internally limited to maximum In.01 rated inverter current. For this the inductance in dr.31 must
be correctly measured or adjusted.
COMBIVIS 5 Scope - H:\CvKebData\F5\SCL\Identifikation\Luv\Luv_Messung_24SM000340F.sc5 - Node 1
COMBIVIS 5 Version 5.6 Registered to: :Horn
Printdate: 19.12.2007 14:59:48 Filedate: 22.12.2004 11:38:30
1017: F5E-S/V2.20 8000rpm
X (us/Division): 80000
CH
Parameter
Set
Y-Scaler (n/Division)
Y-Zero at
A
Ec40 act.absolute pos. el.
0
7282
32768
B
dr31 DSM inductance
0
1,00 mH
5,66 mH
C
Off
D
Off
A
B
Cursor I
Cursor II
Difference:
Ec40 act.absolute pos. el.
[38415] 38415
[26824] 26824
[-11591] -11591
dr31 DSM inductance
[644] 6,44 mH
[484] 4,84 mH
[-160] -1,60 mH
COMBIVIS 5 Scope - H:\CvKebData\F5\SCL\Identifikation\Luv\BMP_Luv_1000Hz.sc5 - Node 1
COMBIVIS 5 Version 5.6 Registered to: :Horn
Printdate: 19.12.2007 14:51:41 Filedate: 19.12.2007 11:52:00
1017: F5E-S/V2.20 8000rpm
X (us/Division): 512000
CH
Parameter
Set
Y-Scaler (n/Division)
Y-Zero at
A
dr31 DSM inductance
0
0,25 mH
14,82 mH
B
AA52 int. data 2
0
7235
170
C
Off
D
Off
A
B
Cursor I
Cursor II
Difference:
dr31 DSM inductance
[1537] 15,37 mH
[1425] 14,25 mH
[-112] -1,12 mH
AA52 int. data 2
[15969] 15969
[-16219] -16219
[-32188] -32188
Ldmax = 6.4 mH
Ldmax = 15.3 mH
Ldmin = 4.8 mH
Ldmin = 14.3 mH
The difference in the inductance is 33%.
The difference in the inductance is 7%.
Содержание COMBIVERT F5-A
Страница 1: ...KEB COMBIVERT F5 A E H 4 4 APPLICATION MANUAL Mat No Rev 00F5AEA K440 1A...
Страница 2: ...Page 1 1 2 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Страница 4: ...Page 1 1 4 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Страница 14: ...Page 1 1 14 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Страница 20: ...Page 2 1 6 COMBIVERT F5 A E H KEB 2012 10 Product Overview...
Страница 28: ...Page 3 1 8 COMBIVERT F5 A E H KEB 2012 10 Control Units...
Страница 34: ...Page 4 1 6 COMBIVERT F5 A E H KEB 2012 10 Fundamentals...
Страница 40: ...Page 4 2 6 COMBIVERT F5 A E H KEB 2012 10 Password input...
Страница 42: ...Page 5 1 2 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Страница 46: ...Page 5 1 6 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Страница 70: ...Page 6 2 20 COMBIVERT F5 A E H KEB 2012 10 Start up...
Страница 140: ...Page 7 3 44 COMBIVERT F5 A E H KEB 2012 10 Digital in and outputs...
Страница 200: ...Page 7 5 38 COMBIVERT F5 A E H KEB 2012 10 Motor data and controller adjustments of the asynchronous motor...
Страница 207: ...Motor data and controller adjustments of the synchronous motor KEB 2012 10 COMBIVERT F5 A E H Page 7 6 7 7...
Страница 238: ...Page 7 7 12 COMBIVERT F5 A E H KEB 2012 10 Speed control...
Страница 254: ...Page 7 8 16 COMBIVERT F5 A E H KEB 2012 10 Torque display and limiting...
Страница 260: ...Page 7 9 6 COMBIVERT F5 A E H KEB 2012 10 Torque control...
Страница 292: ...Page 7 11 26 COMBIVERT F5 A E H KEB 2012 10 Speed measurement...
Страница 432: ...Page 7 14 14 COMBIVERT F5 A E H KEB 2012 10 Parameter sets...
Страница 466: ...Page 7 15 34 COMBIVERT F5 A E H KEB 2012 10 Special functions...
Страница 478: ...Page 7 16 12 COMBIVERT F5 A E H KEB 2012 10 CP Parameter definition...
Страница 480: ...Page 8 1 2 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting 8 1 1 General 8 1 3 8 1 2 Error Messages and their Cause 8 1 3...
Страница 488: ...Page 8 1 10 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting...
Страница 496: ...Page 9 1 8 COMBIVERT F5 A E H KEB 2012 10 General design...
Страница 538: ...Page 11 1 28 COMBIVERT F5 A E H KEB 2012 10 Parameter...
Страница 540: ...Page 12 1 2 COMBIVERT F5 A E H KEB 2008 02 Annex 12 1 1 Index 12 1 3...