Ec.01
———
Ec.11
EC.14 (gear factor slave)
———————————————
EC.15 (gear factor master)
number increments master x
x
The inverse direction of rotation of the slave to the master drive is reached by a negative value for
Ec.14.
Example (adjustments for figure 7.12.3.3 position normalization):
"Normal" speed-controlled operation is programmed in the master, the synchronous module is not activated.
For the slave, encoder channel 1 serves as speed feedback and encoder channel 2 as master position infor-
mation. Both loads shall be moved angular-synchronous, but in opposite direction of rotation.
Adjustment in the slave:
-
PS.00 "Posi / synchronous mode" = synchronous mode
-
CS.01 "Actual source" = channel 1
-
PS.01 „Actual position source“ = channel 2
-
PS.06 "KP for positioning / synchronous" ≠ 0
-
EC.14 "Gear 2 numerator" = -1500
-
EC.15 "Gear 2 denominator" = 525
Typically, an approach to reference point is executed for the slave drive before starting synchronous running,
in order to get the reference between position display of the slave drive and the mechanics of the application.
The reference between master and slave position is done only with activation of the synchronous module.
During activation the master position (= ru.56 "set position") is set equal to the slave position (= ru.54 "actual
position").
7.12.3.4
Synchronous mode / selection of operating mode
The operating mode synchronous mode is selected via parameters PS.00 bit 0...3 or via the control word (Sy.43
or Sy.50)
PS.00: Posi / synchronous mode
Bit
Meaning
Value
Explanation
0..3
Posi-/synchro-
nous mode
0: off
no special operation selected
1: Synchronous
mode
Selection of operating mode "synchronous mode"
2...6
Without function for synchronous mode
7: via control word
The operating modes (synchronous running, positioning mode
or contouring control) are selected via the control word (Sy.43
or Sy.50).
If PS.00 bit 0...3 contains the value 7:
Page 7.12 - 18
COMBIVERT F5-A, -E, -H
© KEB, 2012-10
Posi- and synchronous operating
Содержание COMBIVERT F5-A
Страница 1: ...KEB COMBIVERT F5 A E H 4 4 APPLICATION MANUAL Mat No Rev 00F5AEA K440 1A...
Страница 2: ...Page 1 1 2 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Страница 4: ...Page 1 1 4 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Страница 14: ...Page 1 1 14 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Страница 20: ...Page 2 1 6 COMBIVERT F5 A E H KEB 2012 10 Product Overview...
Страница 28: ...Page 3 1 8 COMBIVERT F5 A E H KEB 2012 10 Control Units...
Страница 34: ...Page 4 1 6 COMBIVERT F5 A E H KEB 2012 10 Fundamentals...
Страница 40: ...Page 4 2 6 COMBIVERT F5 A E H KEB 2012 10 Password input...
Страница 42: ...Page 5 1 2 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Страница 46: ...Page 5 1 6 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Страница 70: ...Page 6 2 20 COMBIVERT F5 A E H KEB 2012 10 Start up...
Страница 140: ...Page 7 3 44 COMBIVERT F5 A E H KEB 2012 10 Digital in and outputs...
Страница 200: ...Page 7 5 38 COMBIVERT F5 A E H KEB 2012 10 Motor data and controller adjustments of the asynchronous motor...
Страница 207: ...Motor data and controller adjustments of the synchronous motor KEB 2012 10 COMBIVERT F5 A E H Page 7 6 7 7...
Страница 238: ...Page 7 7 12 COMBIVERT F5 A E H KEB 2012 10 Speed control...
Страница 254: ...Page 7 8 16 COMBIVERT F5 A E H KEB 2012 10 Torque display and limiting...
Страница 260: ...Page 7 9 6 COMBIVERT F5 A E H KEB 2012 10 Torque control...
Страница 292: ...Page 7 11 26 COMBIVERT F5 A E H KEB 2012 10 Speed measurement...
Страница 432: ...Page 7 14 14 COMBIVERT F5 A E H KEB 2012 10 Parameter sets...
Страница 466: ...Page 7 15 34 COMBIVERT F5 A E H KEB 2012 10 Special functions...
Страница 478: ...Page 7 16 12 COMBIVERT F5 A E H KEB 2012 10 CP Parameter definition...
Страница 480: ...Page 8 1 2 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting 8 1 1 General 8 1 3 8 1 2 Error Messages and their Cause 8 1 3...
Страница 488: ...Page 8 1 10 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting...
Страница 496: ...Page 9 1 8 COMBIVERT F5 A E H KEB 2012 10 General design...
Страница 538: ...Page 11 1 28 COMBIVERT F5 A E H KEB 2012 10 Parameter...
Страница 540: ...Page 12 1 2 COMBIVERT F5 A E H KEB 2008 02 Annex 12 1 1 Index 12 1 3...