Page 7.13 - 22
COMBIVERT F5-A, -E, -H
© KEB, 2012-10
Protective functions
Pn.26: Speed search condition
Bit
Meaning
Explanation
0
1: Speed search after noP
Speed search after the status "no control release"
1
2: Speed search after power-on-
reset
Speed search after power on
2
4: Speed search after reset
Speed search after execution of a reset
3
8: Speed search after auto reset
Speed search after automatic restart
4
16: Speed search after LS
Speed search after the status "standstill (modulation off)"
7.13.6.1
Speed search in open-loop operation
The speed search mode determines the frequency and voltage jumps as well as the maximum load factor with
which the function works. Higher values let the function work faster, lower values make the function "softer".
7.13.6.2
Speed search in closed-loop operation with encoder
In closed-loop operation with activated speed search, the ramp output value is set to the current actual speed.
After the motor flux has been built up, the drive runs up to the setpoint speed.
7.13.6.3
Speed search at asynchronous motors in closed-loop operation without encoder
In closed-loop operation without encoder, the current actual speed must be estimated from the motor model.
For special motors (e.g., high frequency spindles) or applications (e.g., operation in very high field weakening
range), this estimate for the engagement onto a running motor may not work. The speed is then calculated
incorrectly and the drive vibrates or the inverter raises a malfunction.
In these cases, the motor must be stopped by DC braking (see chapter 7.15.) before the drive can be restarted.
Generally, however, the speed search is the most jerk-free and quickest path to switch to a running motor.
Pn.90: Speed search lower limit (ASCL)
Value range: 0.0 - 20.0 %
Default value : 2.0 %*
not set-programmable
* referring to the rated speed of the motor
If the determined speed after speed search is below the limit in pn.90, speed = 0 rpm is preset.
Advantage: The drive is not in "delay" state, thus the motor model remains always active from the start.
7.13.7
Ramp stop
The ramp stop function essentially fulfils two tasks. It reduces the risk of:
-
Overcurrent errors (E.OC) during the acceleration or deceleration phase (only for v/f-characteristic
operation)
-
Overvoltage error (E.OP) during the deceleration phase (in all operating modes)
By stopping the ramp if Pn.24 "ramp stop current level" or Pn.25 ramp stop DC-link voltage level" is exceeded.
Moreover, the ramp stop function can be activated by a digital input.
Pn.22 selects which of the ramps (acceleration, deceleration or both ramps) can be stopped.
Содержание COMBIVERT F5-A
Страница 1: ...KEB COMBIVERT F5 A E H 4 4 APPLICATION MANUAL Mat No Rev 00F5AEA K440 1A...
Страница 2: ...Page 1 1 2 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Страница 4: ...Page 1 1 4 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Страница 14: ...Page 1 1 14 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Страница 20: ...Page 2 1 6 COMBIVERT F5 A E H KEB 2012 10 Product Overview...
Страница 28: ...Page 3 1 8 COMBIVERT F5 A E H KEB 2012 10 Control Units...
Страница 34: ...Page 4 1 6 COMBIVERT F5 A E H KEB 2012 10 Fundamentals...
Страница 40: ...Page 4 2 6 COMBIVERT F5 A E H KEB 2012 10 Password input...
Страница 42: ...Page 5 1 2 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Страница 46: ...Page 5 1 6 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Страница 70: ...Page 6 2 20 COMBIVERT F5 A E H KEB 2012 10 Start up...
Страница 140: ...Page 7 3 44 COMBIVERT F5 A E H KEB 2012 10 Digital in and outputs...
Страница 200: ...Page 7 5 38 COMBIVERT F5 A E H KEB 2012 10 Motor data and controller adjustments of the asynchronous motor...
Страница 207: ...Motor data and controller adjustments of the synchronous motor KEB 2012 10 COMBIVERT F5 A E H Page 7 6 7 7...
Страница 238: ...Page 7 7 12 COMBIVERT F5 A E H KEB 2012 10 Speed control...
Страница 254: ...Page 7 8 16 COMBIVERT F5 A E H KEB 2012 10 Torque display and limiting...
Страница 260: ...Page 7 9 6 COMBIVERT F5 A E H KEB 2012 10 Torque control...
Страница 292: ...Page 7 11 26 COMBIVERT F5 A E H KEB 2012 10 Speed measurement...
Страница 432: ...Page 7 14 14 COMBIVERT F5 A E H KEB 2012 10 Parameter sets...
Страница 466: ...Page 7 15 34 COMBIVERT F5 A E H KEB 2012 10 Special functions...
Страница 478: ...Page 7 16 12 COMBIVERT F5 A E H KEB 2012 10 CP Parameter definition...
Страница 480: ...Page 8 1 2 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting 8 1 1 General 8 1 3 8 1 2 Error Messages and their Cause 8 1 3...
Страница 488: ...Page 8 1 10 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting...
Страница 496: ...Page 9 1 8 COMBIVERT F5 A E H KEB 2012 10 General design...
Страница 538: ...Page 11 1 28 COMBIVERT F5 A E H KEB 2012 10 Parameter...
Страница 540: ...Page 12 1 2 COMBIVERT F5 A E H KEB 2008 02 Annex 12 1 1 Index 12 1 3...