Motor data and controller adjustments of the asynchronous motor
© KEB, 2012-10
COMBIVERT F5-A, -E, -H
Page 7.5 - 15
7
Istfrequenz [U/min]
Motorfluss
Faktor Feldschwächung = 1,2
dr.18
2 * dr.18
0,5
1
Faktor Feldschwächung (dr.20) = 1
=> 1 / x Flussabsenkung
For an optimum motor adaption, this factor may have to be modified .
The flux
reduction is well parametrised, if for every operating point a voltage reserve of approx. 3...10% is
available. I.e., the modulation factor (ru.42) should be (dr.18) ca. 90...97% under nominal
load at the field wea
-
kening speed.
7.5.2.2.3 Magnetisation
current adaption
For large motors, the automatic calculation of the magnetising current occasionally returns values that are too
large. This value can be reduced by adjusting the
parameter "factor flux adaption" (
dr.19).
Whether the automatically calculated magnetising current is too large, can be tested by accelerating the drive
to the field weakening speed (
dr.18) in speed-controlled operation with no load. At this speed, the average va-
lue of the modulation factor should not exceed 90%. If this value is exceeded, the factor "
factor flux adaption"
(dr.19) should be reduced.
7.5.2.3
Vector controlled operation with motor model (with encoder feedback)
The vector controlled operation with motor model is possible only if the electrical characteristic data of a motor
are known. For this operating mode, the motor model calculation must be activated in parameter dS.04.
dS.04 Flux/rotor adaption mode
Bit
Meaning
Value
Explanation
0
Motor model (ASM)
0: off
Activation of the motor model calculation
1: on
7.5.2.3.1
Electrical parameters (equivalent circuit data) of the motor
The electrical characteristic data of the motor must be known for vector controlled operation with motor model.
The parameters DASM stator resistance (dr.06), DASM leakage inductance (dr.07) and DASM rotor resistance
(dr.08) can be taken from a motor data sheet or they can be automatically determined by the KEB COMBIVERT
using the motor
identification. For motors with high power, the resistances are very small (a few mΩ). This can
lead to error in the automatically identification. For these motor, it may be sensible to use the
value from the
Содержание COMBIVERT F5-A
Страница 1: ...KEB COMBIVERT F5 A E H 4 4 APPLICATION MANUAL Mat No Rev 00F5AEA K440 1A...
Страница 2: ...Page 1 1 2 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Страница 4: ...Page 1 1 4 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Страница 14: ...Page 1 1 14 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Страница 20: ...Page 2 1 6 COMBIVERT F5 A E H KEB 2012 10 Product Overview...
Страница 28: ...Page 3 1 8 COMBIVERT F5 A E H KEB 2012 10 Control Units...
Страница 34: ...Page 4 1 6 COMBIVERT F5 A E H KEB 2012 10 Fundamentals...
Страница 40: ...Page 4 2 6 COMBIVERT F5 A E H KEB 2012 10 Password input...
Страница 42: ...Page 5 1 2 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Страница 46: ...Page 5 1 6 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Страница 70: ...Page 6 2 20 COMBIVERT F5 A E H KEB 2012 10 Start up...
Страница 140: ...Page 7 3 44 COMBIVERT F5 A E H KEB 2012 10 Digital in and outputs...
Страница 200: ...Page 7 5 38 COMBIVERT F5 A E H KEB 2012 10 Motor data and controller adjustments of the asynchronous motor...
Страница 207: ...Motor data and controller adjustments of the synchronous motor KEB 2012 10 COMBIVERT F5 A E H Page 7 6 7 7...
Страница 238: ...Page 7 7 12 COMBIVERT F5 A E H KEB 2012 10 Speed control...
Страница 254: ...Page 7 8 16 COMBIVERT F5 A E H KEB 2012 10 Torque display and limiting...
Страница 260: ...Page 7 9 6 COMBIVERT F5 A E H KEB 2012 10 Torque control...
Страница 292: ...Page 7 11 26 COMBIVERT F5 A E H KEB 2012 10 Speed measurement...
Страница 432: ...Page 7 14 14 COMBIVERT F5 A E H KEB 2012 10 Parameter sets...
Страница 466: ...Page 7 15 34 COMBIVERT F5 A E H KEB 2012 10 Special functions...
Страница 478: ...Page 7 16 12 COMBIVERT F5 A E H KEB 2012 10 CP Parameter definition...
Страница 480: ...Page 8 1 2 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting 8 1 1 General 8 1 3 8 1 2 Error Messages and their Cause 8 1 3...
Страница 488: ...Page 8 1 10 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting...
Страница 496: ...Page 9 1 8 COMBIVERT F5 A E H KEB 2012 10 General design...
Страница 538: ...Page 11 1 28 COMBIVERT F5 A E H KEB 2012 10 Parameter...
Страница 540: ...Page 12 1 2 COMBIVERT F5 A E H KEB 2008 02 Annex 12 1 1 Index 12 1 3...