Torque display and -limiting
© KEB, 2012-10
COMBIVERT F5-A, -E, -H
Page 7.8 - 5
7
Picture 7.8.2.2a Field weakening range 1/x reduction
Istfrequenz [U/min]
Moment [Nm]
dr.17
dr.18
2 * dr.18
dr.15
dr.16
0,5 * dr.16
1 / x Absenkung
ds.03 "Feldschwächkennlinie" = 0: aus
The "max. torque FI" (dr.15) is depending on the maximum inverter current and can not be changed.
At default setting the maximum torque in the field weakening is reduced to a 1/x function - because of flux
reduction.
The physical breakdown torque characteristic of the motor is a quare characteristic, i.e. also the maximum
active power in the field weakening range must become smaller.
The square limiting characteristic must be activated if the motor shall be driven to its limits. This is done with
value 2 in point "field weakening characteristic" of parameter dS.03
„current/torque mode“.
dS.03: Current-/torque mode
Bit
Meaning
Value
Explanation
1
Field weakening characte-
ristic
0: off
Activation of the active current limitation in the
field-weakening range
2: on
The limiting characteristic is adapted to the motor with parameter dr.16 „DASM max torque corn. sp“ .
dr.16 = breakdown torque of the motor (at speed dr.18) - safety reserve
Example:
a motor shall have the following rated data:
rated speed: 1470 rpm
rated frequency = 50Hz
rated torque 36Nm
M
rated
/ M
breakdown
= 2.5
selected value for DASM field weakening speed (
dr.18):
1500 rpm
Data sheet value for breakdown torque of the motor at rated
frequency:
2.5 * 36Nm = 90Nm
Safety reserve
25% = 22.5 Nm
dr.16 „DASM max torque corn. sp“ = 90Nm – 22.5Nm = 67.5Nm
Содержание COMBIVERT F5-A
Страница 1: ...KEB COMBIVERT F5 A E H 4 4 APPLICATION MANUAL Mat No Rev 00F5AEA K440 1A...
Страница 2: ...Page 1 1 2 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Страница 4: ...Page 1 1 4 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Страница 14: ...Page 1 1 14 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Страница 20: ...Page 2 1 6 COMBIVERT F5 A E H KEB 2012 10 Product Overview...
Страница 28: ...Page 3 1 8 COMBIVERT F5 A E H KEB 2012 10 Control Units...
Страница 34: ...Page 4 1 6 COMBIVERT F5 A E H KEB 2012 10 Fundamentals...
Страница 40: ...Page 4 2 6 COMBIVERT F5 A E H KEB 2012 10 Password input...
Страница 42: ...Page 5 1 2 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Страница 46: ...Page 5 1 6 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Страница 70: ...Page 6 2 20 COMBIVERT F5 A E H KEB 2012 10 Start up...
Страница 140: ...Page 7 3 44 COMBIVERT F5 A E H KEB 2012 10 Digital in and outputs...
Страница 200: ...Page 7 5 38 COMBIVERT F5 A E H KEB 2012 10 Motor data and controller adjustments of the asynchronous motor...
Страница 207: ...Motor data and controller adjustments of the synchronous motor KEB 2012 10 COMBIVERT F5 A E H Page 7 6 7 7...
Страница 238: ...Page 7 7 12 COMBIVERT F5 A E H KEB 2012 10 Speed control...
Страница 254: ...Page 7 8 16 COMBIVERT F5 A E H KEB 2012 10 Torque display and limiting...
Страница 260: ...Page 7 9 6 COMBIVERT F5 A E H KEB 2012 10 Torque control...
Страница 292: ...Page 7 11 26 COMBIVERT F5 A E H KEB 2012 10 Speed measurement...
Страница 432: ...Page 7 14 14 COMBIVERT F5 A E H KEB 2012 10 Parameter sets...
Страница 466: ...Page 7 15 34 COMBIVERT F5 A E H KEB 2012 10 Special functions...
Страница 478: ...Page 7 16 12 COMBIVERT F5 A E H KEB 2012 10 CP Parameter definition...
Страница 480: ...Page 8 1 2 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting 8 1 1 General 8 1 3 8 1 2 Error Messages and their Cause 8 1 3...
Страница 488: ...Page 8 1 10 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting...
Страница 496: ...Page 9 1 8 COMBIVERT F5 A E H KEB 2012 10 General design...
Страница 538: ...Page 11 1 28 COMBIVERT F5 A E H KEB 2012 10 Parameter...
Страница 540: ...Page 12 1 2 COMBIVERT F5 A E H KEB 2008 02 Annex 12 1 1 Index 12 1 3...