Page 7.12 - 30
COMBIVERT F5-A, -E, -H
© KEB, 2012-10
Posi- and synchronous operating
PS.00: Posi / synchronous mode
Bit
Meaning
Value
Explanation
13 Start with speed
0: PS.00
/ off
The set speed is determined via the Op-Parameters after activation of
the posi module upto the first edge startposi.
8192:
PS.00 / on
The initial setpoint speed is started after activation of the posi module
upto the first edge startposi.
Parameter ru.00 shows, with the progress message "121: ready for positioning", that the positioning mode has
been activated.
But the drive is in position controlled operation only after the first "start positioning". The positi
-
on controlled operation is ended as soon as the positioning module is deactivated.
7.12.4.4
Position normalisation
The resolution of the position display/ setting is done in increments and depends on the used encoder system.
The following cases must be differentiated:
7.12.4.4.1
Position control by the motor encoder
Position control is based on the motor position encoder. I.e., the position values refer to the motor position.
The number of increments per motor revolution amounts to "encoder increments per revolution" x 2 "multiple
evaluation".
If encoder interface 1 (X3A) is used, Ec.01 "encoder 1 (inc/r)" and Ec.07 "enc.1 trigger" must be used for the
calculation.
If encoder interface 2 (X3B) is used, the number of increments per motor revolution must be calculated corre-
sponding of Ec.11 "encoder 2 (inc/r)" and Ec.17 "enc.2 trigger".
If the position control is done directly on the motor encoder, the same encoder channel must be selected in
PS.01 "master source" and cS.01 "act. source".
Value 1 (i.e. gear factor numerator = gear factor denominator) must be selected for the gear factors .
KEB COMBIVERT
F5A-S
or
F5A-S
X3B
Encoder
channel 2
X3A
Encoder
channel 1
M
3~
Example:
Let an incremental encoder with 2500 increments be
connected to encoder channel 1.
The motor shall travel 5.5 revolutions
Revolution in increments:
cS.01 = PS.01 = 0: Channel 1
Ec.04 = EC.05 = 1000 default value
Ec.01 = 2500 increments per revolution
Ec.07 = 2: 4-fold evaluation
→ 2500 x 2
2
x 5.5 = 55000 increments
Содержание COMBIVERT F5-A
Страница 1: ...KEB COMBIVERT F5 A E H 4 4 APPLICATION MANUAL Mat No Rev 00F5AEA K440 1A...
Страница 2: ...Page 1 1 2 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Страница 4: ...Page 1 1 4 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Страница 14: ...Page 1 1 14 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Страница 20: ...Page 2 1 6 COMBIVERT F5 A E H KEB 2012 10 Product Overview...
Страница 28: ...Page 3 1 8 COMBIVERT F5 A E H KEB 2012 10 Control Units...
Страница 34: ...Page 4 1 6 COMBIVERT F5 A E H KEB 2012 10 Fundamentals...
Страница 40: ...Page 4 2 6 COMBIVERT F5 A E H KEB 2012 10 Password input...
Страница 42: ...Page 5 1 2 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Страница 46: ...Page 5 1 6 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Страница 70: ...Page 6 2 20 COMBIVERT F5 A E H KEB 2012 10 Start up...
Страница 140: ...Page 7 3 44 COMBIVERT F5 A E H KEB 2012 10 Digital in and outputs...
Страница 200: ...Page 7 5 38 COMBIVERT F5 A E H KEB 2012 10 Motor data and controller adjustments of the asynchronous motor...
Страница 207: ...Motor data and controller adjustments of the synchronous motor KEB 2012 10 COMBIVERT F5 A E H Page 7 6 7 7...
Страница 238: ...Page 7 7 12 COMBIVERT F5 A E H KEB 2012 10 Speed control...
Страница 254: ...Page 7 8 16 COMBIVERT F5 A E H KEB 2012 10 Torque display and limiting...
Страница 260: ...Page 7 9 6 COMBIVERT F5 A E H KEB 2012 10 Torque control...
Страница 292: ...Page 7 11 26 COMBIVERT F5 A E H KEB 2012 10 Speed measurement...
Страница 432: ...Page 7 14 14 COMBIVERT F5 A E H KEB 2012 10 Parameter sets...
Страница 466: ...Page 7 15 34 COMBIVERT F5 A E H KEB 2012 10 Special functions...
Страница 478: ...Page 7 16 12 COMBIVERT F5 A E H KEB 2012 10 CP Parameter definition...
Страница 480: ...Page 8 1 2 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting 8 1 1 General 8 1 3 8 1 2 Error Messages and their Cause 8 1 3...
Страница 488: ...Page 8 1 10 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting...
Страница 496: ...Page 9 1 8 COMBIVERT F5 A E H KEB 2012 10 General design...
Страница 538: ...Page 11 1 28 COMBIVERT F5 A E H KEB 2012 10 Parameter...
Страница 540: ...Page 12 1 2 COMBIVERT F5 A E H KEB 2008 02 Annex 12 1 1 Index 12 1 3...