Adjustments:
● PS.00:
PS.00: Posi / synchronous mode
Bit
Meaning
Value
Explanation
0...2
Posi / synchro-
nous mode
5: Posi mode
Activation of the positioning mode
4
Positioning /
target speed
16: PS.31 /
PS.25
The maximum profile speed is preset via
PS.31 "index / speed".
The drive shall stop at the target, so the target speed must be
PS.25 = 0 for all blocks.
All other bits can remain at the factory settings for this example and are explained in the following chapters.
●
Block 0 defines the start position
→
PS.28 = 0
●
Input I3 serves as "start positioning"
→
PS.29 = 64: I3 (X2A.12)
●
The maximum profile speed is calculated from:
PS.31 (max. speed setting %) x oP.10 (max. reference forward)
To change this analog via AN2, the following adjustments must be made:
(also see chapter 7.15.8: analog parameter setting)
An.30: Sel. REF input./AUX function = 2112
(factory setting)
An.53: Analog para. setting source
= 0:AUX input (ru.53)
(factory setting)
An.54: Analog para. setting destina-
tion
= 131Fh
(bus address PS.31)
An.55: Analog para. setting. / offset = 0
(factory setting)
An.56: Analog para. setting max.
value
= 1000
= 100%
oP.10: max. setpoint forward
= 1500 rpm
(max.possible profile speed)
An.30 defines that AN2 serves as AUX input.
An.53 defines that the parameter value is preset via the AUX input.
An.54 defines the bus address of the parameter to be set by analog input (here,
PS.31)
(the bus address of a parameter can be read in Combivis in, e.g., the work list).
An.56 defines the maximum value (unnormalised) for parameter
PS.31. Then the normalised value for
PS.31 is calculated as follows:
100% AUX value = maximum value (An.56) x resolution of the parameter PS.31 (0.1%) =
1000 x 0.1% = 100%
The value for PS.31 corresponds to the AUX value.
Then the maximum profile speed is calculated as follows:
ru.63:
Profile speed =
PS.31 x oP.10 = AUX x oP.10
●
block 0
→
PS.23: Index / selection = 0
Position = 0
→
PS.24: Index / position = 0
Posi- and synchronous operating
© KEB, 2012-10
COMBIVERT F5-A, -E, -H
Page 7.12 - 47
7
Содержание COMBIVERT F5-A
Страница 1: ...KEB COMBIVERT F5 A E H 4 4 APPLICATION MANUAL Mat No Rev 00F5AEA K440 1A...
Страница 2: ...Page 1 1 2 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Страница 4: ...Page 1 1 4 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Страница 14: ...Page 1 1 14 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Страница 20: ...Page 2 1 6 COMBIVERT F5 A E H KEB 2012 10 Product Overview...
Страница 28: ...Page 3 1 8 COMBIVERT F5 A E H KEB 2012 10 Control Units...
Страница 34: ...Page 4 1 6 COMBIVERT F5 A E H KEB 2012 10 Fundamentals...
Страница 40: ...Page 4 2 6 COMBIVERT F5 A E H KEB 2012 10 Password input...
Страница 42: ...Page 5 1 2 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Страница 46: ...Page 5 1 6 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Страница 70: ...Page 6 2 20 COMBIVERT F5 A E H KEB 2012 10 Start up...
Страница 140: ...Page 7 3 44 COMBIVERT F5 A E H KEB 2012 10 Digital in and outputs...
Страница 200: ...Page 7 5 38 COMBIVERT F5 A E H KEB 2012 10 Motor data and controller adjustments of the asynchronous motor...
Страница 207: ...Motor data and controller adjustments of the synchronous motor KEB 2012 10 COMBIVERT F5 A E H Page 7 6 7 7...
Страница 238: ...Page 7 7 12 COMBIVERT F5 A E H KEB 2012 10 Speed control...
Страница 254: ...Page 7 8 16 COMBIVERT F5 A E H KEB 2012 10 Torque display and limiting...
Страница 260: ...Page 7 9 6 COMBIVERT F5 A E H KEB 2012 10 Torque control...
Страница 292: ...Page 7 11 26 COMBIVERT F5 A E H KEB 2012 10 Speed measurement...
Страница 432: ...Page 7 14 14 COMBIVERT F5 A E H KEB 2012 10 Parameter sets...
Страница 466: ...Page 7 15 34 COMBIVERT F5 A E H KEB 2012 10 Special functions...
Страница 478: ...Page 7 16 12 COMBIVERT F5 A E H KEB 2012 10 CP Parameter definition...
Страница 480: ...Page 8 1 2 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting 8 1 1 General 8 1 3 8 1 2 Error Messages and their Cause 8 1 3...
Страница 488: ...Page 8 1 10 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting...
Страница 496: ...Page 9 1 8 COMBIVERT F5 A E H KEB 2012 10 General design...
Страница 538: ...Page 11 1 28 COMBIVERT F5 A E H KEB 2012 10 Parameter...
Страница 540: ...Page 12 1 2 COMBIVERT F5 A E H KEB 2008 02 Annex 12 1 1 Index 12 1 3...