
7.12.5.2
Contouring control mode / settings
All parameters can be specified in bus-synchronous operation. Typically, this operating mode is used for the
contouring control mode. The activation of this mode is done in parameter PS.00 or via the control word.
PS.00: Posi / synchronous mode
Bit
Meaning
Value
Explanation
0...2
Posi / synchro-
nous mode
0...5
Without function for contouring control
6: Contouring
control
Selection of operating mode contouring control
7: via control word
The operating modes are selected via the control word
(Sy.43 or Sy.50).
Sy.50: control word (low) /
Sy.43: control word (long)
Bit
Meaning
Value
Explanation
12 / 13
Operating
mode
0: off
4096: synchronous
running
Selection of operating mode synchronous running
8192: positioning
Selection of operating mode positioning
12288: Contouring
control
Selection of operating mode contouring control
To activate the contouring control mode, the digital input assigned with the function "posi / synchronous" must
be set.
In contouring control mode, the drive is positioned via the setting of a position setpoint value in the bus-syn-
chronous grid. The control, therefore, does not give the final target position but the set point position for each
individual cycle.
The inverter calculates the speed required to reach the position setpoint in one bus cycle. The setting of the
position setpoint can be done via PS.24 "index position" or via PS.34 "ctm position".
PS.33 "contouring mode setpoint source" determines which parameter provides the setpoint position.
PS.33: Source contouring mode position
Bit
Meaning
Value
Explanation
0
Source posi-
tion setting
0: PS.34
The position is stored as set position by writing on PS.34. The value is
stored as set position by writing on PS.24.
1: PS.34, 24
1, 2
Source
speed setting
0: calculated
Parameter „set speed value“ (SY.52) has 1 rpm in all resolution
modes. Parameter „reference setting“oP.03 is used in order to select a
high resolution.
2: SY.52
4: oP.03
7.12.5.3
Contouring control mode / write / read data
For the bus-synchronous operation, the read and write data that are to be transmitted with each bus cycle must
be defined. In the parameters Sy.24, Sy.26 and Sy.28, the bus addresses of the parameters that are to be pro-
vided bus-synchronously by the customer control must be set.Only 3 parameters can be selected (one 32 bit
parameter and two 16 bit parameters).
The set position (32 bit parameter) must always be preset bus-synchronously for the contouring control mode.
Page 7.12 - 78
COMBIVERT F5-A, -E, -H
© KEB, 2012-10
Posi- and synchronous operating
Содержание COMBIVERT F5-A
Страница 1: ...KEB COMBIVERT F5 A E H 4 4 APPLICATION MANUAL Mat No Rev 00F5AEA K440 1A...
Страница 2: ...Page 1 1 2 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Страница 4: ...Page 1 1 4 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Страница 14: ...Page 1 1 14 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Страница 20: ...Page 2 1 6 COMBIVERT F5 A E H KEB 2012 10 Product Overview...
Страница 28: ...Page 3 1 8 COMBIVERT F5 A E H KEB 2012 10 Control Units...
Страница 34: ...Page 4 1 6 COMBIVERT F5 A E H KEB 2012 10 Fundamentals...
Страница 40: ...Page 4 2 6 COMBIVERT F5 A E H KEB 2012 10 Password input...
Страница 42: ...Page 5 1 2 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Страница 46: ...Page 5 1 6 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Страница 70: ...Page 6 2 20 COMBIVERT F5 A E H KEB 2012 10 Start up...
Страница 140: ...Page 7 3 44 COMBIVERT F5 A E H KEB 2012 10 Digital in and outputs...
Страница 200: ...Page 7 5 38 COMBIVERT F5 A E H KEB 2012 10 Motor data and controller adjustments of the asynchronous motor...
Страница 207: ...Motor data and controller adjustments of the synchronous motor KEB 2012 10 COMBIVERT F5 A E H Page 7 6 7 7...
Страница 238: ...Page 7 7 12 COMBIVERT F5 A E H KEB 2012 10 Speed control...
Страница 254: ...Page 7 8 16 COMBIVERT F5 A E H KEB 2012 10 Torque display and limiting...
Страница 260: ...Page 7 9 6 COMBIVERT F5 A E H KEB 2012 10 Torque control...
Страница 292: ...Page 7 11 26 COMBIVERT F5 A E H KEB 2012 10 Speed measurement...
Страница 432: ...Page 7 14 14 COMBIVERT F5 A E H KEB 2012 10 Parameter sets...
Страница 466: ...Page 7 15 34 COMBIVERT F5 A E H KEB 2012 10 Special functions...
Страница 478: ...Page 7 16 12 COMBIVERT F5 A E H KEB 2012 10 CP Parameter definition...
Страница 480: ...Page 8 1 2 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting 8 1 1 General 8 1 3 8 1 2 Error Messages and their Cause 8 1 3...
Страница 488: ...Page 8 1 10 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting...
Страница 496: ...Page 9 1 8 COMBIVERT F5 A E H KEB 2012 10 General design...
Страница 538: ...Page 11 1 28 COMBIVERT F5 A E H KEB 2012 10 Parameter...
Страница 540: ...Page 12 1 2 COMBIVERT F5 A E H KEB 2008 02 Annex 12 1 1 Index 12 1 3...