DcSetup programme
Positioning module UVE8112, IMD10
used to set an output of the final stage that should be used to separate the limit switch of this axis
from the eme
rgency stop chain.
Reference Run dialogue box
The reference run serves to define the zero point of an axis. For this, the axis moves with the “Drive
into the switch” speed in one direction, until the switch indicated becomes active. Afterwards, the axis
(
s wi
oint. This is then the zero point of the axis. The reference acceleration should amount to about 1/10
alogue box” on page 57) in order to go easy on the
slowly) move
th the “Drive out of the switch” speed in the other direction, until the switch switches
p
of the axis acceleration (see “Acceleration di
64
Содержание IMD1
Страница 1: ...DC servo positioning module with CanOpen interface UVE8112 IMD10 www isel com ...
Страница 66: ...DcSetup programme Positioning module UVE8112 IMD10 66 ...
Страница 113: ...Positioning module UVE8112 IMD10 Appendix 113 Appendix UVE8112 package dimensions ...
Страница 114: ...Appendix Positioning module UVE8112 IMD10 114 IMD10 package dimensions ...