Description of the drive module
Positioning module UVE8112, IMD10
LEDs UVE8112
Via the LEDs on the front, it is possible to indicate the existence of the two main supply voltages.
Furthermore, the current mode of operation of the module can be viewed here (STS1 and STS2).
For this, see: "Status diagram" on page 75 and "Device control" on page 87.
In the Operation Enable state, the two related LEDs (STS1 and STS2) are used to show the current
motor current in the negative and positive direction. Concerning this, the maximum brightness
corresponds to the peak current.
In case of a fault (Fault state), the two-digit error code of the current fault is given via a blinking code.
1
st
digit: number of blinking impulses of both status LEDs.
2
nd
digit: number of blink impulses of LED STS2.
See "EMCY" on page 74 for the description of the error code.
In case of a missing enabling signal, all three LEDs (STS1, STS2 and CAN) blink about once every
1.5 seconds.
+5V
+70V
Drive status
Switch On Disabled
Ready To Switch On
Switched On
Operation Enable
NMT state OPERATIONAL
Fault
Blinking interval about 0.5 s
CAN warning
No enabling signal (Input 4)
Blinking interval about 1.5 s
STS1
STS2
CAN
NMT state PRE-OPERATIONAL