Positioning module UVE8112, IMD10 CanOpen
protocol
111
The sub-index 2 helps to carry out the following settings:
Configure test
input
Internal mode of operation
0
Back to normal mode of operation
1
Test signal current control
2
Test signal velocity control
3
Test signal position control
4
Encoder test positive direction
5
Encoder test negative direction
6
Determine maximum velocity
7
Velocity control with ramp profile
8 Following
error
9
Speed amplification factor kv
Trace Data
Index Sub Name
Type
Attrib Map Default
value
Meaning
2081 00 Trace
data
Domain
RO
N
Data field for internal
registrations of courses of
current and velocities etc.