Goodrive350-19 series VFD for crane
Commissioning guidelines
-54-
5.5 Tower crane rotating without vortex in space voltage vector control
5.5.1 Wiring
Braking resistor
VFD
(+)
PB
M
3~
M
3~
T
S
R
T
S
R
W
V
U
S1
S2
S3
FWD run
REV run
COM
Fault reset
S4
Coast to stop
Running
VFD fault output
RO1A
RO1B
RO1C
RO2A
RO2B
RO2C
Multi-step speed giving terminal 1
Multi-step speed giving terminal 2
S5
S7
COM
Multi-step speed giving terminal 3
S6
PW
+24V
PW
+24V
EC-IO-502-00
IO card
Figure 5-7 Wiring for tower crane rotating (without vortex) in space voltage vector control
Note: If the wiring is performed according to Figure 5-7, most VFD parameters need no adjustment. If
the onsite function terminals are inconsistent with the terminals shown in the figure, adjust the input
and output terminal functions according to the actual wiring after selecting this application macro.
5.5.2 Commissioning procedure
1. Check the wiring and ensure the wiring is proper.
2. Set P00.18=1 to restore to default settings.
3. Set motor nameplate parameters in P02.
4. Set P90.00=15 to select the application macro for tower crane slewing without vortex in space
voltage vector control.
5. Perform low-speed trial run.
5.5.3 Macro parameters (P90.00=15)
Function
code
Name
Setting
Remarks
P00.01
Channel of running
commands
1
Terminal
P00.06
Setting channel of A
6
Multi-step speed running