Goodrive350-19 series VFD for crane
Commissioning guidelines
-93-
Function
code
Name
Description
Setting
Hundreds
place:
Whether
to
enable
master/slave to send/receive data
0: Enable
1: Disable
Lifting VFD parameters
Function
code
Name
Description
Setting
Communication
P28.00
Master/slave mode
1: The local device is the master.
1
P28.01
Master/slave
communication data
selection
0: CAN
0
P28.02
Master/slave control
mode
Ones place: Master/slave running mode
selection
6: Master/slave mode 6
Used for master/slave height transfer, in which
the master sends the measured height to the
slave. (You can check P94.05 to obtain the
height sent from the master and P94.32 to
obtain the height sent to the slave.)
Tens place: Slave start command source
0: Master
1: Determined by
Hundreds place: Whether to enable
master/slave to send/receive data
0: Enable
1: Disable
0x116
Height measuring
P93.08
Enabling height
measuring
0
–1
0: Disable
1: Enable internal measuring (motor encoder)
(In closed-loop mode, the encoder measures
the speed and height.)
2: Enable external measuring (HDI)
(In open- and closed-loop modes, the pulley
encoder measures the height.)
Note: When P93.08=2, P20.15=0 indicates
1