Goodrive350-19 series VFD for crane
Basic operation guidelines
-180-
Setting
Function
Description
fault input
stops due to the fault.
59
Switch from VC to space
voltage vector control
When the function is enabled in stopped state, space
voltage vector control is used.
60
Switch to VC control
When the function is enabled in stopped state, VC is used.
61
Switch PID polarities
Used to switch the output polarity of PID. It is used together
with P09.03.
62
Switch to SVC1 control
(open-loop vector control
1)
Switch from closed-loop vector control to open-loop vector
control.
63
Enable servo
When the thousands place of P21.00 enables servo, the
servo enabling terminal is valid, which controls the VFD to
enter zero servo control. At this time, the start command is
not needed.
64
Limit on forward running
Forward rotation position limit for stop. When receiving this
signal during forward rotation, the VFD stops.
65
Limit on reverse running
Reverse rotation position limit for stop. When receiving this
signal during reverse rotation, the VFD stops.
66
Clear encoder counting
Used to clear the position counting value.
67
Increase pulses
When the terminal function is valid, the pulse input is
increased according to the P21.27 pulse speed.
68
Enable pulse superposition
Pulse increment and pulse decrement can be valid only
after pulse superimposition is enabled.
69
Decrease pulses
When the terminal function is valid, the pulse input is
decreased according to the P21.27 pulse speed.
70
Electronic gear selection
When the terminal is valid, the proportional numerator is
switched to the P21.30 numerator of the 2nd command
ratio.
71
Switch to the master
When the terminal is valid, the switchover from the slave to
the master can be implemented.
72
Switch to the slave
When the terminal is valid, the switchover from the master
to the slave can be implemented.
73
Enable the VFD
When the terminal is valid, the VFD is enabled.
74
Contactor feedback signal Contactor status feedback.
75
Brake feedback signal
Brake status feedback.
76
Operating lever zero-point
position
When the terminal is valid, the operating level sets the
zero-point input signal.
77
Graded reference terminal
1
Five terminals can be used to implement graded speed
setting.