Goodrive350-19 series VFD for crane
Function parameter list
-309-
Function
code
Name
Description
Default
Modify
P22.09
Spindle
scale-division
angle 3
Setting range: 0.00
–359.99
45.00
○
P22.10
Spindle
scale-division
angle 4
Setting range: 0.00
–359.99
60.00
○
P22.11
Spindle
scale-division
angle 5
Setting range: 0.00
–359.99
90.00
○
P22.12
Spindle
scale-division
angle 6
Setting range: 0.00
–359.99
120.00
○
P22.13
Spindle
scale-division
angle 7
Setting range: 0.00
–359.99
180.00
○
P22.14 Spindle drive ratio
Used to set the reduction ratio of the spindle and
the mounting shaft of the encoder.
Setting range: 0.000
–30.000
1.000
○
P22.15
Spindle zero-point
communication
setting
is used to set spindle zero-point
offset. If the selected spindle zero point
is
, the final spindle zero point is
the sum of
Setting range: 0
–39999
0
○
P22.16
Reserved
0
–65535
0
○
P22.17
Reserved
0
–65535
0
○
P22.18
Rigid tapping
selection
Ones place: Enabling selection
0: Disable (This function can be enabled through
a terminal (configured with function 58)
1: Enable (internally)
Tens place: Analog port selection
0: Disable
1: AI1
2: AI2
3: AI3
0x00
◎
P22.19
Analog filter time
of rigid tapping
0.0ms
–1000.0ms
1.0ms
○
P22.20 Max. frequency of 0.00
–400.00Hz
50.00Hz
○