Goodrive350-19 series VFD for crane
Commissioning guidelines
-114-
Function
code
Name
Description
Default
11: Closed-loop winching (for lifting in mineral
wells and winches)
12: Open-loop winching (for lifting in mineral
wells and winches)
13: Construction elevator mode 2 (for
medium-speed elevator application)
14: Tower crane slewing without vortex in
closed-loop vector control
15: Tower crane slewing without vortex in space
voltage vector control
P90.02
User-defined
application macro
setting
0
–3
0: None
1: Enter the settings of user-defined application
macro 1
2: Enter the settings of user-defined application
macro 2
3: Enter the settings of user-defined application
macro 3
0
P90.03
Method for terminals to
switch application
macros
0
–5
0: No switchover
1: Switch from motor 1 to motor 2
2: Switch from motor 1 to motor 3
3: Switch from the master to the slave
4: Switch from the salve to the master
5: Switch to SVC1 control (open-loop vector
control 1)
0