Goodrive350-19 series VFD for crane
Function parameter list
-226-
Function
code
Name
Description
Default
Modify
setting range: 0.0
–100.0% (of the max.
frequency)
P03.40
Enabling inertia
compensation
0: Disable
1: Enable
0
○
P03.41
Upper limit of
inertia
compensation
torque
The max. inertia compensation torque is limited
to prevent inertia compensation torque from
being too large.
Setting range: 0.0
–150.0% (of the motor rated
torque)
10.0%
○
P03.42
Inertia
compensation
filter times
Filter times of inertia compensation torque, used
to smooth inertia compensation torque.
Setting range: 0
–10
7
○
P03.43
Inertia
identification
torque
Due to friction force, it is required to set certain
identification torque for the inertia identification
to be performed properly.
0.0
–100.0% (of the motor rated torque)
10.0%
○
P03.44
Enabling inertia
identification
0: No operation
1: Enable
0
◎
P03.45
Current loop
proportional
coefficient after
autotuning
0
–65535
0
○
P03.46
Current integral
proportional
coefficient after
autotuning
0
–65535
0
○
P04 group
––V/F control
Function
code
Name
Description
Default
Modify
P04.00
V/F curve setting
of motor 1
This group of function code defines the V/F
curve of motor 1 to meet the needs of different
loads.
0: Straight-line V/F curve, applicable to constant
torque loads
1: Multi-point V/F curve
2: Torque-down V/F curve (power of 1.3)
3: Torque-down V/F curve (power of 1.7)
0
◎