Goodrive350-19 series VFD for crane
Function parameter list
-350-
Function
code
Name
Description
Default
Modify
DEC position limit uses the similar rule.
Bi-directional limit: When the upward/downward
DEC limit position is reached, the
upward/downward slow speed zone is entered,
which indicates that both the upward and
downward speeds are limited.
(Terminal command mode)
P91.35
DEC position limit
restricted
frequency
0.00
–20.00Hz
10.00Hz
○
P91.37
Enabling HDO
based vortex
control for tower
crane slewing
0
–1
0: HDO keeps the same function as specified by
1: HDO is used as PWM signal for voltage
adjustment output.
P91.37=1: Enable the tower crane rotating
vortex control. HDO connects to the PWM input
of the turbulence module. You can enable the
output voltage of the turbulence module to
change with the frequency by setting
P91.38
–P91.47.
0
◎
P91.38
Frequency f0
(Max.
output frequency)
setting range: 0.00Hz
range: 0.0%
–100.0%
Segmented adjustment is performed based on
the cycle ratio and frequency.
Duty cycle
Frequency
P91.39
P91.38
P91.40
P91.42
P91.44
P91.46
P91.41
P91.43
P91.45
P91.47
50.00Hz
○
P91.39
Duty ratio
corresponding to
frequency f0
100.0%
○
P91.40
Frequency f1
40.00Hz
○
P91.41
Duty ratio
corresponding to
frequency f1
80.0%
○
P91.42
Frequency f2
20.00Hz
○
P91.43
Duty ratio
corresponding to
frequency f2
40.0%
○
P91.44
Frequency f3
10.00Hz
○
P91.45
Duty ratio
corresponding to
frequency f3
20.0%
○