Goodrive350-19 series VFD for crane
Expansion card
-461-
+24V
PE
COM
S4
S3
S2
S1
HDIB
PW
HDIA
SI-
CO+
CO-
EX+
EX-
R
S
T
U
V
W
U
V
W
M3~
PG
AO+
AO-
BO+
BO-
ZO+
ZO-
pulse A
pulse B
A2+
A2-
B2+
B2-
REV running
FWD running
CNC
PLC
Upper computer
SI+
Fault reset
Z2+
Z2-
A.6.4 Multi-function incremental PG card (EC-PG505-12)
The terminals are arranged as follows:
The dual in-line package (DIP) switch SW1 is used to set the voltage class (5V or 12V) of the power
supply of the encoder. The DIP switch can be operated with an auxiliary tool.
PE
AO+
BO+
ZO+
A1+
B1+
Z1+
A2+
B2+
Z2+
PWR
GND
AO-
BO-
ZO-
A1-
B1-
Z1-
A2-
B2-
Z2-
PGND
Indicator definition:
Indicator
Definition
Function
LED1