Goodrive350-19 series VFD for crane
Function parameter list
-231-
Function
code
Name
Description
Default
Modify
P04.25
Oscillation control
2
eliminate such phenomenon.
setting range: 0
–100
setting range: 0
–100
setting range: 0.00Hz
(Max.
output frequency)
30.00Hz
○
P04.26 Energy-saving run
0: Disable
1: Automatic energy-saving run
In light-load state, the motor can adjust the
output voltage automatically to achieve energy
saving.
0
◎
P04.27
Voltage setting
channel
0: Keypad (The output voltage is determined by
1: AI1
2: AI2
3: AI3
4: HDIA
5: Multi-step speed running (The setting is
determined by group P10.)
6: PID
7: Modbus communication
8: PROFIBUS/CANopen/DeviceNet
communication
9: Ethernet communication
10: HDIB
11: EtherCAT/Profinet communication
12: Programmable expansion card
13: 216 communication
0
○
P04.28
Voltage set
through keypad
The function code is the voltage digital setting
when "keypad" is selected as the voltage setting
channel.
Setting range: 0.0%
–100.0%
100.0%
○
P04.29
Voltage increase
time
Voltage increase time means the time needed
for the VFD to accelerate from min. output
voltage to the max. output frequency.
Voltage decrease time means the time needed
for the VFD to decelerate from the max. output
frequency to min. output voltage.
Setting range: 0.0
–3600.0s
5.0s
○
P04.30
Voltage decrease
time
5.0s
○