Goodrive350-19 series VFD for crane
Function parameter list
-329-
P90 group
––Functions special for cranes
Function
code
Name
Description
Default
Modify
P90.00
Hoisting
application macro
setting
0
–18
0: Common application mode
1: Lifting mode 1 (in open-loop vector control)
2: Lifting mode 2 (in closed-loop vector control)
3: Horizontal moving mode (in space voltage
vector control)
4: Tower crane slewing mode
5: Conical motor application mode
6: User-defined application macro 1 (when
P90.02=1)
7: User-defined application macro 2 (when
P90.02=2)
8: User-defined application macro 3 (when
P90.02=3)
9: Lifting mode 3 (in space voltage vector
control)
10: Construction elevator mode
11: Closed-loop winching (for lifting in mineral
wells and winches)
12: Open-loop winching (for lifting in mineral
wells and winches)
13: Construction elevator mode 2 (for
medium-speed elevator application)
14: Tower crane slewing without vortex in
closed-loop vector control
15: Tower crane slewing without vortex in space
voltage vector control
16
–18: Reserved
0
◎
P90.01
Terminal-switched
application macro
setting
0
◎
P90.02
User-defined
application macro
setting
0
–3
1: Enter the settings of user-defined application
macro 1
2: Enter the settings of user-defined application
macro 2
3: Enter the settings of user-defined application
macro 3
0
◎
P90.03
Method for
terminals to switch
application
0
–5
0: No switchover
1: Switch from motor 1 to motor 2
0
◎