![INVT GD350-004G-4 Скачать руководство пользователя страница 85](http://html1.mh-extra.com/html/invt/gd350-004g-4/gd350-004g-4_operation-manual_2085703085.webp)
Goodrive350 series high-performance multifunction VFD
Basic operation guidelines
-76-
Function
code
Name
Description
Default
value
P02.04
Rated voltage of
asynchronous motor 1
0
–1200V
Depends
on model
P02.05
Rated current of
asynchronous motor 1
0.8
–6000.0A
Depends
on model
P02.06
Stator resistance of
asynchronous motor 1
0.001
–65.535Ω
Depends
on model
P02.07
Rotor resistance of
asynchronous motor 1
0.001
–65.535Ω
Depends
on model
P02.08
Leakage inductance of
asynchronous motor 1
0.1
–6553.5mH
Depends
on model
P02.09
Mutual inductance of
asynchronous motor 1
0.1
–6553.5mH
Depends
on model
P02.10
No-load current of
asynchronous motor 1
0.1
–6553.5A
Depends
on model
P02.15
Rated power of synchronous
motor 1
0.1
–3000.0kW
Depends
on model
P02.16
Rated frequency of
synchronous motor 1
0.01Hz
–P00.03 (Max. output frequency)
50.00Hz
P02.17
Number of pole pairs of
synchronous motor 1
1
–50
2
P02.18
Rated voltage of
synchronous motor 1
0
–1200V
Depends
on model
P02.19
Rated current of
synchronous motor 1
0.8
–6000.0A
Depends
on model
P02.20
Stator resistance of
synchronous motor 1
0.001
–65.535Ω
Depends
on model
P02.21
Direct-axis inductance of
synchronous motor 1
0.01
–655.35mH
Depends
on model
P02.22
Quadrature-axis inductance
of synchronous motor 1
0.01
–655.35mH
Depends
on model
P02.23
Counter-emf constant of
synchronous motor 1
0
–10000
300
P05.01
–
P05.06
Function of multi-function
digital input terminal (S1
–S4,
HDIA,HDIB)
35: Switch from motor 1 to motor 2
/
P08.31
Switching between motor 1
and motor 2
0x00
–0x14
Ones: Switchover channel
0: Switch over by
0x00