Goodrive350 series high-performance multifunction VFD
Function parameter list
-231-
Function
code
Name
Description
Default
value
Modify
0: Speed control
1: Torque control
2: Position control
Hundreds: Motor number
0: Motor 1
1: Motor 2
P17.41
Upper limit of the
torque when
motoring
0.0%
–300.0% (of the motor rated current)
180.0%
●
P17.42
Upper limit of
braking torque
0.0%
–300.0% (of the motor rated current)
180.0%
●
P17.43
Upper limit
frequency of
forward running
of torque control
0.00
–P00.03
50.00Hz
●
P17.44
Upper limit
frequency of
reverse running
of torque control
0.00
–P00.03
50.00Hz
●
P17.45
Inertia
compensation
torque
-100.0%
–100.0%
0.0%
●
P17.46
Friction
compensation
torque
-100.0%
–100.0%
0.0%
●
P17.47 Motor pole pairs 0
–65535
0
●
P17.48
VFD overload
count value
0
–65535
0
●
P17.49
Frequency set by
A source
0.00
–P00.03
0.00Hz
●
P17.50
Frequency set by
B source
0.00
–P00.03
0.00Hz
●
P17.51
PID proportional
output
-100.0%
–100.0%
0.0%
●
P17.52
PID integral
output
-100.0%
–100.0%
0.0%
●
P17.53
PID differential
output
-100.0%
–100.0%
0.0%
●