![INVT GD350-004G-4 Скачать руководство пользователя страница 264](http://html1.mh-extra.com/html/invt/gd350-004g-4/gd350-004g-4_operation-manual_2085703264.webp)
Goodrive350 series high-performance multifunction VFD
Function parameter list
-255-
Function
code
Name
Description
Default
value
Modify
0: No filter
1: Filter
Bit3: Enable/disable pulse reference
frequency-division output filter
0: No filter
1: Filter
Bit4: Enable/disable pulse reference filter
0: No filter
1: Filter
Bit5: Pulse reference filter mode
0: Self-adaptive filter
1: Use P24.19 filter parameters
Bit6: Frequency- division output source setting
(valid only for incremental encoders)
0: Encoder signals
1: Pulse reference signals
Bits 7
–15: Reserved
P24.18
Encoder pulse
filter width
0
–63
The filtering time is P24
.18×0.25 μs. The value 0
or 1 indicates 0.25 μs.
2
○
P24.19
Pulse reference
filter width
0
–63
The filtering time is P24.19
×0.25 μs. The value 0
or 1 indicates 0.25 μs.
2
○
P24.20
Pulse number of
pulse reference
0
–16000
1024
◎
P24.21
Enable angle
compensation of
synchronous
motor
0
–1
0
○
P24.22
Switchover
frequency
threshold of
speed
measurement
mode
0
–630.00Hz
1.00Hz
○
P24.23
Synchronous
motor angle
compensation
coefficient
-200.0
–200.0%
100.0%
○