![INVT GD350-004G-4 Скачать руководство пользователя страница 279](http://html1.mh-extra.com/html/invt/gd350-004g-4/gd350-004g-4_operation-manual_2085703279.webp)
Goodrive350 series high-performance multifunction VFD
Function parameter list
-270-
Function
code
Name
Description
Default Modify
4: High-speed pulse HDI
Tens place: Multiplier of max. tension (P90.12)
0: 1
1: 10
P90.11
Tension set
through keypad
0.0
–100.0%
10.0%
○
P90.12
Max. tension
When the tens place of P90.10 is 0, the setting
range is 0
–60000N.
When the tens place of P90.10 is 1, the setting
range is (0
–60000)*10N.
1000N
○
P90.13
Roll diameter
calculation mode
0: Not calculated
1: AI1
2: AI2
3: AI3
4: High-speed pulse HDI
5: Linear speed
6: Thickness (of wire)
7: Thickness (of strip)
0
◎
P90.14
Roll diameter
calculation delay
time
0.0
–100.0s
1.0s
○
P90.15 Min. roll diameter 0.0mm
–P90.16
50.0mm
○
P90.16
Max. roll
diameter
P90.15
–5000.0mm
1000.0
mm
○
P90.17
Initial roll
diameter 1
P90.15
–P90.16 (mm)
100.0
mm
○
P90.18
Initial roll
diameter 2
P90.15
–P90.16 (mm)
100.0
mm
○
P90.19
Initial roll
diameter 3
P90.15
–P90.16 (mm)
100.0
mm
○
P90.20
Linear speed roll
diameter
calculation filter
time
0.000
–60.000s
2.000s
○
P90.21
Linear speed roll
diameter
calculation
restriction
0x00
–0x11
Ones place:
0:No
1: Restrict changes in reverse direction
0x00
○