![INVT GD350-004G-4 Скачать руководство пользователя страница 393](http://html1.mh-extra.com/html/invt/gd350-004g-4/gd350-004g-4_operation-manual_2085703393.webp)
Goodrive350 series high-performance multifunction VFD
Dimension drawings
-384-
W1
H1
D1
W2
H2
98.0
D2
W2
W3
W4
H4
H2
H3
Figure C-10 Flange mounting diagram for 380V 90
–110kW models
W1
D1
W2
W2
D2
H2
H1
W4
W3
W2
W2
H4
H2
H3
Figure C-11 Flange mounting diagram for 380V 132
–200kW models
Table C
–2 Flange mounting dimensions of 380V VFDs (unit: mm)
VFD model
W1
W2
W3
W4
H1
H2
H3
H4
D1
D2
Mounting
hole
Fixing
screw
1.5kW
–2.2kW 150.2 115 130 7.5 234 220 190 13.5 185 65.5
Ø 5
M4
4kW
–5.5kW 150.2 115 130 7.5 234 220 190 13.5 201
83
Ø 5
M4
7.5kW
170.2 131
150
9.5
292 276
260
6
192 84.5
Ø 6
M5
11kW
–15kW 191.2 151 174 11.5 370 351 324
12
220
113
Ø 6
M5
18.5kW
–22kW 266 250 224
13
371 250 350.6 20.3 208
104
Ø 6
M5
30kW
–37kW
316
300
274
13
430 300
410
55
223 118.3
Ø 6
M5
45kW
–75kW
352
332
306
12
580 400
570
80
258 133.8
Ø 9
M8
90kW
–110kW 418.5 389.5 361 14.2 600 370 559 108.5 330 149.5
Ø 10
M8
132kW
–200kW 500 180 480
60
870 850
796
37
360 178.5
Ø 11
M10