![INVT GD350-004G-4 Скачать руководство пользователя страница 81](http://html1.mh-extra.com/html/invt/gd350-004g-4/gd350-004g-4_operation-manual_2085703081.webp)
Goodrive350 series high-performance multifunction VFD
Basic operation guidelines
-72-
Function
code
Name
Description
Default
value
5: Modbus/Modbus TCP communication
6: PROFIBUS/CANopen/DeviceNet
communication
7: Ethernet communication
8: Pulse frequency HDIB
9: EtherCAT/PROFINET/EtherNet IP
communication
10: Programmable card
11: Reserved
Note:
For these settings, 100% corresponds to
the motor rated current.
P03.19
Setting source of
braking torque
upper limit
0: Keypad (P03.21)
1: AI1
2: AI2
3: AI3
4: Pulse frequency HDIA
5: Modbus/Modbus TCP communication
6: PROFIBUS/CANopen/DeviceNet
communication
7: Ethernet communication
8: Pulse frequency HDIB
9: EtherCAT/PROFINET/EtherNet IP
communication
10: Programmable card
11: Reserved
Note:
For these settings, 100% corresponds to
the motor rated current.
0
P03.20
Electromotive
torque upper limit
set through
keypad
0.0
–300.0% (of the motor rated current)
180.0%
P03.21
Braking torque
upper limit set
through keypad
0.0
–300.0% (of the motor rated current)
180.0%
P17.09
Motor output
torque
-250.0
–250.0%
0.0%
P17.15
Torque reference
value
-300.0
–300.0% (of the motor rated current)
0.0%