Goodrive350 series high-performance multifunction VFD
Basic operation guidelines
-44-
5.4.2 Editing a parameter list
The parameters in the parameter list in stopped state can be added as needed (through the menu of
user defined home parameters), and the list can also be edited such as "Move up", "Move down",
"Delete from the list", and "Restore default". The edit function is shown in the following.
GD350
16:02:35
Place top
Move up
Delete from the list
16:02:35
Fwd
Local
Ready
Stopped-state parameters
Running-state parameters
GD350
16:02:35
P17.00
:
Set Freq
P17.11
:
DC Bus Volt
P17.12
:
HDIB/A/S4/3/2/1
P17.13
:
RO2/RO1/HDO/Y1
P17.26
:
Current Oper Time
P17.15
:
Motor Trq Ref
GD350
Fwd
Local
Ready
Fwd
Local
Ready
Move down
Restore default
Back Edit OK
Back Home Sele
Back Home Sele
Figure 5-10 List edit diagram 1
Press
key to enter edit interface, select the operation needed, and press the
key,
key or
key to confirm the edit operation and return to the previous menu (parameter list), the
returned list is the list edited. If the
key or
key is pressed in edit interface without
selectingan edit operation, it will return to the previous menu (parameter list remain unchanged).
Note:
For the parameter objects in the list header, move-up operation will be invalid, and the same
principle can be applied to the parameter objects in the list footer; after deleting a certain parameter,
the parameter objects under it will be moved up automatically.
The items in the parameter list in running state can be added as needed (through the menu of user
defined home parameters), and the list can also be edited such as "Place top", "Move up", "Move
down", "Delete from the list", and "Restore default parameters". The edit function is shown in the
interface below.
GD350
16:02:35
Place top
GD350
16:02:35
Stopped-state parameters
Running-state parameters
Fwd
Local
Ready
Fwd
Local
Ready
Move up
Delete from the list
Move down
Restore default parameters
16:02:35
P17.01
:
OutpFreq
P17.00
:
Set Freq
P17.11
:
DC Bus Volt
P17.03
:
Outp Volt
P17.04
:
Outp Cur
P17.05
:
Motor Speed
GD350
Fwd
Local
Ready
Back Home Sele
Back Edit OK
Back Home Sele
Figure 5-11 List edit diagram 2
The parameters of user defined parameter setting can be added, deleted or adjusted as needed,
such as "Place top", "Move up", "Move down", "Delete from the list", and "Restore default parameters";
the adding function can be set in a certain function code in a function group. The edit function is
shown in the figure below.
16:02:35
Grouping parameters
State parameter
Motor parameter autotuning
Parameter copy/Restore default
System setting
Fwd
Local
Ready
User defined parameter setting
GD350
16:02:35
P00.00: Speed Ctrl Run Cmd
P00.02: Comm Cmd Channel
P00.03: Max Output Freq
P00.04: RunFreq Up Limit
P00.05: RunFreq Low Limit
Fwd
Local
Ready
P00.01: Run Cmd Channel
16:02:35
Place top
Fwd
Local
Ready
Move up
Delete from the list
Move down
Restore default parameters
GD350
GD350
Back Home Sele
Back Edit Sele
Back Home Sele
Figure 5-12 List edit diagram 3