Selenio
TM
BNP User Guide, Release 3.7.1
232
- DVB-CA Configuration
Monitoring SCG
Use the
Monitor SCG
dialog to view a
Basic
or
Extension
display of CP counters.
1.
From the
DVB-CA
tab page, click on the
SCG
tab.
2.
Right-click on a selected SCG and select
Monitor SCG
from the popup menu.
The
Monitor SCG
dialog is now in view.
3.
At the
View Type:
field, use the pull-down menu to choose the
Basic
or
Extension
view
).
Figure 168. Monitor SCG dialog
•
The
Basic
view displays data between the SCS and the MUX.
•
The
Extension
view additionally displays counters that are collected between the SCS and the
ECMG.
CP Duration (100ms)
Specify the Crypto Period for this SCG. Specifies the default crypto period
for the BNP chassis in 100 millisecond increments.
• Check the
Use global config
box to follow the default parameter as
specified in the
DVB-CA Global Configuration fields
table.
• Un-check the
Use global config
box to specify a different Crypto Period
for the SCG.
• Default is set to
Use global config.
Scramble Level
Specifies the default scramble level used to configure the scrambler for
this SCG.
• TS is currently the only option.
• This field is read-only.
•
Use global config
box is read-only and defaulted to checked.
Disable
Checking this button will disable all scrambling on the SCG, changing all
scrambled programs to clear.
• Default is unchecked.
Table 98.
Create SCG dialog - Internal EIS mode parameters (Continued)
Field