Selenio
TM
BNP User Guide, Release 3.7.1
168
- Working with PIDs
4.
From the pull-down menus, select the
Stream Category
,
Stream Type
, and
PID
.
If you check
Multiple ES
, you can simultaneously define sequential unreferenced PIDs by entering
the number of Elementary Streams (
Number of ES
) and the
Start PID
.
5.
At the
Add Elementary Stream
dialog, click
OK
to
present the new PID in the
Inputs
column for the
Ghost Program
Table 84.
Add Elementary Stream
Field
Description/Values
TS
Read-only field that identifies the transport stream associated with this
configuration.
Program
Read-only field that identifies the program associated with this configuration.
Multiple ES (checkbox)
Enable (check) or disable (un-check) multiple elementary streams for this TS.
Stream Category
Choose either Audio, Data, or Video to define the stream category for this ES.
Stream Type
As dependent on your selection for
Stream Category
, select an option from
this range to define the selected stream category. See also the following
topics in this section:
•
.
•
.
•
Number of ES
For Multiple TS, value to set number of elementary streams allowable for this
TS, in the range 1 - 32.
Start PID
For Multiple TS, value to set beginning PID.
End PID
For Multiple TS, value to set end PID.
PID (0..8190)