Selenio
TM
BNP User Guide, Release 3.7.1
179
- Managing PMT and ES Descriptors
Figure 128. Manage Descriptor Rules - Rules Added
4.
Click
Cancel
to close the window.
describes the fields available in the
Add Descriptor Rule
menu.
Table 85.
Manage Descriptor Rules fields
Field
Description
TS
This field is read-only. Displays the Transport Stream ID and type for which
the rule will apply.
Program
This field is read-only. Displays the name of the program for which the rule
will apply.
Name
For reference use only when appending (or adding) an output program
descriptor. Do
not
enter data in this field when removing a descriptor.
Action
Specify which action is to occur for this rule. Choices are:
•
Append Descriptor:
adds the specified descriptor to the PMT of the output
stream. The descriptor is appended to the end of the program descriptor
loop if the PID is 0, or the ES descriptor loop if the configured PID matches
the elementary stream PID.
•
Remove Descriptor:
removes the specified descriptor from the PMT of the
output stream. If the BNP doesn’t find a match descriptor in the PMT, no
action is taken.
PID
Specifies the PID of the stream. Valid range is from 0 to 8190. If the
descriptor is a program descriptor, enter a value of 0. Otherwise, enter the
elementary stream (ES) PID value; the descriptor rule is applied to this ES.
• Clicking the green DEC button in this field will toggle the field from decimal
to hex view.
• Clicking the green HEX button in this field will toggle the field from hex to
decimal view.
for an example of the DEC to HEX toggle view.