Selenio
TM
BNP User Guide, Release 3.7.1
155
- Grooming - Mapping
Manual Recovery Procedures
The BNP supports the ability to manually switch between the Primary and Backup programs. Use the
steps provided in this section to perform a manual recovery:
1.
From the
Outputs panel
of the
Grooming -> Mapping
window, right-click the desired program
and select
Display Grooming
from the pop-up menu.
The
Current Program Mapping and Schedule
window opens (
).
Figure 93.
Program Redundancy - Manual Recovery
2.
Select the scheduled program and right-click.
3.
From the pop-up menu, select
Switch to Backup
.
The
Switch to Backup
option is available when the selected program is already in the
Manual Recovery
to Primary Program
operation mode. (The
Automatic Recovery to Primary Program
mode does not
allow staying in the Backup Program.)
above illustrates the
Manual Recovery
selection for program redundancy operation on
individual programs. This can be used for the
Manual Recovery Primary Program
procedure following
an
Automatic Failure to Backup Program,
or for toggling between primary and backup programs for
test purposes.
To recover all programs, from the main
Element Manager
window, select
Maintenance
(
Alt m
)-
->
Regroom
. See “Regrooming” on page 198 for additional information.