Selenio
TM
BNP User Guide, Release 3.7.1
194
- Configuring the Time Offset Table (TOT)
3.
After you click the
Log in
button, the BNP will timeout and
display the BNP unreachable message. Click
OK
to dismiss
this message.
The BNP Log In screen is now displayed, with fields in which
to enter the SNMP Community String Read and Write
strings.
Enter the new
Read
and/or
Write
community strings to match the entries you changed in
above.
4.
Click the
Log in
button.
The BNP will log you in as normal.
Note:
You will need to log in as described above for any workstation that is accessing the Element
Manager for the first time after the
SNMP Read / Write Community Strings
have been
changed.
Configuring the Time Offset Table (TOT)
The TOT conveys additional information about summer and winter time periods and gives the local
time offset with respect to UTC for different countries or regions. If the TOT is locally generated, user
interaction is required to define the country or region in which the receiver is operated. The BNP
supports the required DVB tables, including TOT.
Use the
Set up Time Offset table (TOT)
dialog for this configuration.
Menu Path
From the
Element Manager
, select
Maintenance
(Alt
m
)-
-> Setup Time Offset table
(TOT)
(Alt
t
)
and
).