72
FUNCTION:
SET ANTIKERCHUNKER FILTER INTERVAL TIME RX2
FUNCTION CODE:
141
PURPOSE:
Allows changes to the interval timer - the time before the Linker IIa restarts the
rx2 Antikerchunker filter
HOW TO USE:
1.
Key up
2.
Enter the SET ANTIKERCHUNKER FILTER INTERVAL TIME RX2 function code
3.
Unkey
4.
The controller sends the ENTER NEXT DATA indication
5.
Key up
6.
Enter the time in seconds
7.
Unkey
8.
The controller sends the COMMAND ACCEPTED indication
9.
Now the rx2 Antikerchunker filter interval time is set to the entered value
The range of the interval timer is 10s to 2500 seconds. This timer starts after the rx2 antikerchunker times out. When
this timer times out the rx2 antikerchunker filter is again started.
This feature is available starting with version 1.31 of the Linker II / Linker IIa software.
FUNCTION:
ENABLE_RX1_TONE_RX2_ACTIVE
FUNCTION CODE:
142
PURPOSE
This function will allow a rx1 courtesy tone even with rx2 cos active
HOW TO USE:
1.
Key up
2.
Enter the ENABLE_RX1_TONE_RX2_ACTIVE function code
3.
Unkey
4.
The controller sends the COMMAND ACCEPTED indication
5.
Now the rx1 courtesy tone will occur even if rx2 is active
This function, when enabled, will allow the courtesy tone from rx1 to occur when the rx1 cos becomes non-active and
the rx2 cos is still active.
To make this function permanent (Function stays active after power up or reset) the SAVE STATUSES function
(function # 87) must be used.
This feature is available starting with version 1.32 of the Linker II / Linker IIa software.