37
FUNCTION:
SET NUMBER OF REMOTE BASE MEMORIES
FUNCTION CODE:
71
PURPOSE:
To tell the controller the number of memories the remote base is using
HOW TO USE:
1.
Key up
2.
Enter the SET NUMBER OF REMOTE BASE MEMORIES function code
3.
Unkey
4.
The controller sends the ENTER NEXT DATA indication
5.
Key up
6.
Enter the number of memories the remote base has that the controller will increment through
7.
Unkey
8.
The controller sends the COMMAND ACCEPTED indication
9.
The number of remote base memories is set
The time range is from 1 memory to 254 memories. If a value is entered outside these limits the controller will not
save the entered value, it will give the ERROR or BAD VALUE indication (B in CW) and the function will be ended.
When deciding the value for this function the actual number of memories that appears on the radio’s display is what
needs to be programmed in. The number to enter here is the actual number of memories that shows up on the remote
base radios display when you go from the first memory to the last.
FUNCTION:
SET HANG TIME
FUNCTION CODE:
72
PURPOSE
Sets the time TX 1 is on after the receivers become inactive
HOW TO USE:
1.
Key up
2.
Enter the SET HANG TIME code
3.
Unkey
4.
The controller sends the ENTER NEXT DATA code
5.
Key up
6.
Enter the hang time in seconds
7.
Unkey
8.
The controller sends the COMMAND ACCEPTED indication
9.
The new hang time value is stored
The range of the timer is from 0.1 seconds to 25 seconds. If a value is entered outside these limits the controller will
not save the entered value, it will give the ERROR or BAD VALUE indication (B in CW) and the function will be
ended. The timer is accurate to about 0.2 seconds and has a minimum of about a quarter of a second
To enter a decimal point use the ' * ' key. To enter the value 1.2 sec enter ' 1*2 ' on your DTMF keypad.