45
FUNCTION:
SAVE STATUSES
FUNCTION CODE:
87
PURPOSE:
Makes the current statuses permanent
HOW TO USE:
1.
Key up
2.
Enter the SAVE STATUSES function code
3.
Unkey
4.
The controller sends the COMMAND ACCEPTED indication
5.
The controller’s selected statuses will now be stored in EEPROM
The statuses need to be changed before using Save statuses. Save statuses just stores them the way it finds them from
the controllers temporary RAM memory to the controllers permanent EEPROM memory.
This command will put the value of the statuses listed below in EEPROM memory so they are as currently in RAM
when the controller is powered up again. If the Save statuses function is not used and any of these values are changed
the values will go back to what they were before power up. The factory defaults are also shown below;
1.
TX ENABLED
Default = TRUE
2.
ID ENABLED
Default = TRUE
3.
BEEP ENABLED
Default = TRUE
4.
AUXILIARY 1 TIMER ENABLED
Default = TRUE
5. DTMF MUTING ENABLED Default = TRUE
6. ENABLE TX FAN Default = FALSE
7. RX 1 COR IN AND / OR MODE Default = FALSE
8. RX 2 COR IN AND / OR MODE Default = FALSE
9. DTMF CONTROL ON RX 2 INPUT Default = FALSE
10. Port 2 Mode status Default = HALF DUPLEX
11. FORCE CTCSS ON Default = FALSE
FUNCTION:
ENABLE TIMED TX FAN ON AUXILIARY 1 OUTPUT
FUNCTION CODE:
88
PURPOSE:
To enable control for a transmitter fan for TX 1 on auxiliary 1 output
HOW TO USE:
1. Key up
2. Enter the ENABLE TIMED TX FAN ON AUXILIARY 1 OUTPUT function code
3.
Unkey
4.
The controller sends the COMMAND ACCEPTED indication
5.
The TX 1 fan output is now enabled on the auxiliary 1 output
This function will turn on its output when TX 1 comes on and remain on for a preset time after TX 1 goes off. The
output used for this function is the auxiliary 1 output. The auxiliary 1 output timer is used for the fan timer. It starts
when TX 1 goes off. To set the time for this function use the SET AUXILIARY 1 OUTPUT TIMEOUT TIME
function (function code 69).
The ENABLE TIMED TX FAN ON AUXILIARY 1 OUTPUT command will enable the TX fan. If the TX fan was
disabled on power up the TX FAN will again be disabled on power up (or warm reset) unless you use the SAVE
STATUSES (Function number 87). If you ENABLE TIMED TX FAN ON AUXILIARY 1 OUTPUT and then use
the SAVE STATUSES function the TX fan will always be enabled when a power or warm reset occurs.