71
FUNCTION:
DISABLE ANTIKERCHUNKER FILTER RX2
FUNCTION CODE:
139
PURPOSE
Disables the rx2 Antikerchunker filter
HOW TO USE:
1.
Key up
2.
Enter the DISABLE ANTIKERCHUNKER FILTER RX2 function code
3.
Unkey
4.
The controller sends the COMMAND ACCEPTED indication
5.
Now the rx2 Antikerchunker filter is enabled
To make this function permanent (Function stays active after power up or reset) the SAVE STATUSES function
(function # 87) must be used.
This feature is available starting with version 1.31 of the Linker II / Linker IIa software.
FUNCTION:
SET ANTIKERCHUNKER FILTER DELAY RX2
FUNCTION CODE:
140
PURPOSE
Allows changes to the rx2 Antikerchunker delay time
HOW TO USE:
1.
Key up
2.
Enter the SET ANTIKERCHUNKER FILTER DELAY RX2 function code
3.
Unkey
4.
The controller sends the ENTER NEXT DATA indication
5.
Key up
6.
Enter the time in seconds
7.
Unkey
8.
The controller sends the COMMAND ACCEPTED indication
9.
Now the rx2 Antikerchunker filter is set to the entered value
The range of the delay timer is 0.1s to 25s. This timer sets the amount of time the receiver needs to be active before
the antikerchunker filter stops filtering. .Use the ‘*’ key for the decimal point. You may enter up to 4 digits (the
decimal point counts as a digit).
This feature is available starting with version 1.31 of the Linker II / Linker IIa software.