66
FUNCTION:
REPORT THE CURRENT REMOTE BASE MEMORY NUMBER
FUNCTION CODE:
129
PURPOSE:
Tells you what memory the remote base is set to
HOW TO USE:
1.
Key up
2.
Enter the REPORT THE CURRENT REMOTE BASE MEMORY NUMBER function code
3.
Unkey
4.
The controller now reports the current remote base memory number in morse code
This function is available starting with V1.17 of the Linker II and Linker IIa software.
FUNCTION:
SET MEMORY REPORT AFTER MEMORY SELECT
FUNCTION CODE:
130
PURPOSE:
This function allows the user to enable or disable the reporting of the memory after the
remote base memory has been selected by the controller.
HOW TO USE:
1.
Key up
2.
Enter the SET MEMORY REPORT AFTER MEMORY SELECT function code
3.
Unkey
4.
The controller sends ENTER NEXT DATA indication
5.
Enter a ‘1’ to allow the memory report or a ‘0’ to Not allow the memory report
6.
Unkey
7.
The controller sends the COMMAND ACCEPTED indication
8.
If a ‘1’ was entered the current remote base memory will be reported in morse code.
This function will allow you to enable or disable the memory number reporting after a remote base memory is
selected. Entering a ‘1’ enables the report after the remote base memory is selected and entering a ‘0’ disables the
report after a remote base memory is selected.
The default status (factory default) is the memory report will occur after the remote base memory is selected.
To keep the current setting of this function you must use the SAVE STATUSES command (command #87). This
will insure the current status of this setting will be maintained upon power up and reset.
This feature is available starting with version 1.19 of the Linker II / Linker IIa software.