48
FUNCTION:
AND RX 1 COS AND CTCSS INPUTS
FUNCTION CODE:
93
PURPOSE:
Requires an AND condition for a valid RX1 ACTIVE condition
HOW TO USE:
1.
Key up
2.
Enter the SET RX1 COS TO AND function code
3.
Unkey
4.
The controller sends the COMMAND ACCEPTED indication
5.
The controller is now in AND mode on receiver 1 (RX1, port 1)
This function when enabled will set the receiver #1 input (RX1) to require both the RX1 main input and the RX1
CTCSS input to be active (AND condition) before an active receiver condition is recognized by the controller.
To make this function permanent (Function stays active after power up or reset) the SAVE STATUSES function
(function # 87) must be used.
FUNCTION:
SET RX 2 CTCSS OFF LEVEL
FUNCTION CODE:
94
PURPOSE:
Sets the voltage which when reached the control will consider this input to be off
HOW TO USE:
1.
Key up
2.
Enter the SET RX 2 CTCSS OFF LEVEL function code
3.
Unkey
4.
The controller sends the ENTER NEXT DATA indication
5.
Key up
6.
Enter the CTCSS voltage ( 1v to 9v) that when reached the controller should consider RX 2 CTCSS to be OFF
7.
Unkey
8.
When the controller sends the COMMAND ACCEPTED indication these values have been entered
9.
The new RX 2 CTCSS input voltage off level is stored in EEPROM
10.
A reset or power down / power up action will be necessary to have the new value for the RX 2 CTCSS input
The voltage entered can be from 1V to 9V and can be entered down to 0.01V. If the voltage value is not in the 1V to
9V range the controller will not save the entered voltage and it will give the ERROR or BAD VALUE indication (B in
CW) .
This sets the RX 2 CTCSS off voltage. When setting the voltage care should be taken not to set it to the exact voltage
measured because the actual voltage may not always be exactly the same. It is a good idea to set the voltage at a level
that is not quite at the final voltage the CTCSS reaches. This can help avoid problems if the voltage changes slightly.