61
FUNCTION:
DISABLE ANTIKERCHUNKER FILTER
FUNCTION CODE:
119
PURPOSE
Disables the Antikerchunker filter
HOW TO USE:
1.
Key up
2.
Enter the DISABLE ANTIKERCHUNKER FILTER function code
3.
Unkey
4.
The controller sends the COMMAND ACCEPTED indication
5.
Now the Antikerchunker filter is enabled
To make this function permanent (Function stays active after power up or reset) the SAVE STATUSES function
(function # 87) must be used.
FUNCTION:
SET ANTIKERCHUNKER FILTER DELAY
FUNCTION CODE:
120
PURPOSE
Allows changes to the Antikerchunker delay time
HOW TO USE:
1.
Key up
2.
Enter the SET ANTIKERCHUNKER FILTER DELAY function code
3.
Unkey
4.
The controller sends the ENTER NEXT DATA indication
5.
Key up
6.
Enter the time in seconds
7.
Unkey
8.
The controller sends the COMMAND ACCEPTED indication
9.
Now the Antikerchunker filter is set to the entered value
The range of the delay timer is 0.1s to 25s. This timer sets the amount of time the receiver needs to be active before
the antikerchunker filter stops filtering. .Use the ‘*’ key for the decimal point. You can only enter 4 digits (the
decimal point counts as a digit).
Содержание Linker IIa