59
FUNCTION:
DEACTIVATE BEACON MODE
FUNCTION CODE:
115
PURPOSE
Sets the IDer back to normal mode – disables the Beacon function
HOW TO USE:
1.
Key up
2.
Enter the DEACTIVATE BEACON MODE function code
3.
Unkey
4.
The controller sends the COMMAND ACCEPTED indication
5.
The controller will now not be in Beacon mode
To make this function permanent (function stays active after power up or reset) the SAVE STATUSES function
(function # 87) must be used. This is a factory default (see set factory defaults, function #66)
FUNCTION:
SET TIME FOR PULSE ON AUXILIARY 3
FUNCTION CODE:
116
PURPOSE
To set the time the Auxiliary 3 pulse will be on when auxiliary 3 is pulsing
HOW TO USE:
1.
Key up
2.
Enter the SET TIME FOR PULSE ON AUXILIARY 3 Function code
3.
Unkey
4.
The controller sends the ENTER NEXT DATA indication
5.
Key up
6.
Enter the time in seconds for the Auxiliary 3 pulse time
7.
Unkey
8.
The controller sends the COMMAND ACCEPTED
9.
The value is changed.
The time range is from .004 second to 1.000 second. If a value is entered outside these limits the controller will not
save the entered value, it will give the ERROR indication (B in CW) and the function will be ended. Use the ‘*’ key
for the decimal point. You can only enter 4 digits (the decimal point counts as a digit).