FUNCTION:
CLEAR CONTROL OPERATOR MODE
DTMF CODE:
61
PURPOSE:
Takes the controller out of the control operator mode
HOW TO USE:
1.
Key up
2.
Enter the CLEAR CONTROL OPERATOR MODE function code
3.
Unkey
4.
The controller sends the COMMAND ACCEPTED indication
5.
The controller will not be in the Control operator mode.
If the control operator mode is enabled during the Setup mode it will have no effect until exiting the Setup mode.
Upon exiting the Setup mode the controller will be in Control operator mode. The controller can be both in Setup
mode and control operator mode at the same time but the Setup mode has priority.
The control operator mode operates exactly like the user mode except it will allow access to DTMF command lines
that are set to be accessible in the control operator mode.
When this command is used the control will be in the User mode.
FUNCTION:
ENABLE_IDER
FUNCTION CODE:
62
PURPOSE:
Enables the IDer
HOW TO USE:
1.
Key up
2.
Enter the ENABLE_IDER function code
3.
Unkey
4.
The controller sends the COMMAND ACCEPTED indication
5.
The controller’s IDer will now be enabled...
If the IDer was not enabled on power up the save statuses function will need to be run. This will store the new IDer
status along with others. This needs to be done or the IDer status will return to the way it was the last time the
controller was powered up when a warm reset or power on reset occur.
To make this function permanent (Function stays active after power up or reset) the SAVE STATUSES function
(function # 87) must be used.