62
FUNCTION:
SET ANTIKERCHUNKER FILTER INTERVAL TIME
FUNCTION CODE:
121
PURPOSE:
Allows changes to the interval timer - the time before the Linker IIa restarts the
Antikerchunker filter
HOW TO USE:
1.
Key up
2.
Enter the SET ANTIKERCHUNKER FILTER INTERVAL TIME function code
3.
Unkey
4.
The controller sends the ENTER NEXT DATA indication
5.
Key up
6.
Enter the time in seconds
7.
Unkey
8.
The controller sends the COMMAND ACCEPTED indication
9.
Now the Antikerchunker filter interval time is set to the entered value
The range of the interval timer is 10s to 2500 seconds. This timer starts after the antikerchunker times out. When this
timer times out the antikerchunker filter is again started.
FUNCTION:
SET PREBEEP TIME
FUNCTION CODE:
122
PURPOSE
Sets the time from when RX1 is determined to be off and the courtesy tone starts
HOW TO USE:
1.
Key up
2.
Enter the SET PREBEEP TIME function code
3.
Unkey
4.
The controller sends the ENTER NEXT DATA indication
5.
Key up
6.
Enter the time in seconds
7.
Unkey
8.
The controller sends the COMMAND ACCEPTED indication
9.
Now the Prebeep time is set to the entered value
The minimum Prebeep time that can be set is 0.1 seconds, the maximum Prebeep time that can be set is 25 seconds. If
a value is entered outside this range the controller will send a Morse code “B” (for Bad data) and the bad data will not
be saved. .Use the ‘*’ key for the decimal point. You can only enter 4 digits (the decimal point counts as a digit).