PCI
Hot-Plug
Manager
Access
The
installation
instructions
for
hot-pluggable
PCI
adapters
refer
you
to
these
procedures
when
it
is
appropriate
to
perform
them.
Note:
A
PCI
adapter
is
only
hot-pluggable
if
the
PCI
adapter
is
supported
for
hot-plug
applications.
See
the
PCI
Adapter
Placement
Reference
,
order
number
SA38-0538.
Accessing
Hot-Plug
Management
Functions
Note:
Removing
or
installing
a
Hot-Pluggable
PCI
adapter
requires
the
system
administrator
to
take
the
PCI
adapter
offline
prior
to
performing
the
operation.
Before
taking
an
adapter
offline,
the
devices
attached
to
the
adapter
must
be
taken
offline
as
well.
This
action
prevents
a
service
representative
or
user
from
causing
an
unexpected
outage
for
system
users.
For
additional
information
about
taking
an
adapter
offline
or
removing
it
from
the
system
configuration,
see
the
AIX
System
Management
Guide:
Operating
System
and
Devices
.
This
publication
is
located
on
the
AIX
Documentation
CD.
The
documentation
information
is
made
accessible
by
loading
the
documentation
CD
onto
the
hard
disk
or
by
mounting
the
CD
in
the
CD-ROM
drive.
To
access
the
hot-plug
menus,
do
the
following:
1.
Log
in
as
root
user.
2.
At
the
command
line,
type
smitty
.
3.
Select
Devices
.
4.
Select
PCI
Hot
Plug
Manager
and
press
Enter.
5.
The
PCI
Hot-Plug
Manager
menu
displays.
Return
to
the
procedure
that
directed
you
here.
The
following
section
contains
a
description
of
the
menu
options.
Chapter
10.
Removal
and
Replacement
Procedures
423
Содержание RS/6000 Enterprise Server M80
Страница 1: ...RS 6000 Enterprise Server Model M80 Eserver pSeries 660 Model 6M1 Service Guide SA38 0571 01...
Страница 10: ...x Service Guide...
Страница 14: ...xiv Service Guide...
Страница 16: ...xvi Service Guide...
Страница 22: ...Data Flow 4 Service Guide...
Страница 28: ...CEC Drawer Front View With Bezel Removed 3 2 1 1 Power On Off LED 2 Fan 2 3 Fan 1 10 Service Guide...
Страница 30: ...CEC Card Cage Rear of CEC drawer viewed from top cover removed 12 Service Guide...
Страница 84: ...66 Service Guide...
Страница 176: ...158 Service Guide...
Страница 376: ...358 Service Guide...
Страница 430: ...412 Service Guide...
Страница 445: ...3 Insert the memory module firmly into the connector Chapter 10 Removal and Replacement Procedures 427...
Страница 476: ...7 Remove the screws that connect the carrier to the CD ROM Replacement Replace in reverse order 458 Service Guide...
Страница 485: ...Chapter 11 Parts Information This chapter contains parts information for the system 467...
Страница 486: ...CEC Drawer Card Assembly 9 468 Service Guide...
Страница 488: ...CEC Drawer Backplane 5 2a 1 2 3 4 470 Service Guide...
Страница 490: ...CEC Drawer Power Supplies 1 2 3 4 5 6 7 8 9 472 Service Guide...
Страница 492: ...CEC Drawer Fan Assemblies 2 1 3 4 5 6 8 9 10 11 12 13 7 14 474 Service Guide...
Страница 494: ...I O Drawer 1 2 3 4 5 6 7 8 9 10 11 16 17 18 19 20 12 14 13 13 15 21 22 23 24 26 25 27 476 Service Guide...
Страница 496: ...7 8 9 10 6 1 2 3 4 4 5 478 Service Guide...
Страница 508: ...490 Service Guide...
Страница 520: ...502 Service Guide...
Страница 522: ...504 Service Guide...
Страница 526: ...508 Service Guide...
Страница 542: ...error Handle unexpected modem responses expect 8 r or 7 r or 6 r or 4 r or 3 r delay 2 done 524 Service Guide...
Страница 558: ...540 Service Guide...
Страница 565: ......
Страница 566: ...Printed in USA September 2001 SA38 0571 01...
Страница 567: ...Spine information RS 6000 Enterprise Server Model M80 Eserver pSeries 660 Model 6M1 Service Guide SA38 0571 01...