Table
7.
Service
Processor
Error
Codes
(continued)
Error
Code
Description
Action/
Possible
Failing
FRU
4067
0523
6xx
bus
processor
runtime
diagnostics
detected
memory
DIMM
fault
Memory
DIMM
13,
riser
2
Location:
U1.1-P1-M2.13
4067
0524
6xx
bus
processor
runtime
diagnostics
detected
memory
DIMM
fault
Memory
DIMM
14,
riser
2
Location:
U1.1-P1-M2.14
4067
0525
6xx
bus
processor
runtime
diagnostics
detected
memory
DIMM
fault
Memory
DIMM
21,
riser
2
Location:
U1.1-P1-M2.21
4067
0526
6xx
bus
processor
runtime
diagnostics
detected
memory
DIMM
fault
Memory
DIMM
22,
riser
2
Location:
U1.1-P1-M2.22
4067
0527
6xx
bus
processor
runtime
diagnostics
detected
memory
DIMM
fault
Memory
DIMM
29,
riser
2
Location:
U1.1-P1-M2.29
4067
0528
6xx
bus
processor
runtime
diagnostics
detected
memory
DIMM
fault
Memory
DIMM
30,
riser
2
Location:
U1.1-P1-M2.30
4067
052D
6xx
bus
processor
runtime
diagnostics
detected
memory
DIMM
group
fault
Memory
octal
C,
riser
2
Location:
U1.1-P1-M2.5
x8
4067
052E
6xx
bus
processor
runtime
diagnostics
detected
memory
DIMM
group
pair
A
fault
Memory
quad
C
odd,
riser
2
Location:
U1.1-P1-M2.5
x4
4067
052F
6xx
bus
processor
runtime
diagnostics
detected
memory
DIMM
group
fault
Memory
quad
C
even,
riser
2
Location:
U1.1-P1-M2.6
x4
4067
0531
6xx
bus
processor
runtime
diagnostics
detected
memory
DIMM
fault
Memory
DIMM
7,
riser
2
Location:
U1.1-P1-M2.7
4067
0532
6xx
bus
processor
runtime
diagnostics
detected
memory
DIMM
fault
Memory
DIMM
8,
riser
2
Location:
U1.1-P1-M2.8
4067
0533
6xx
bus
processor
runtime
diagnostics
detected
memory
DIMM
fault
Memory
DIMM
15,
riser
2
Location:
U1.1-P1-M2.15
4067
0534
6xx
bus
processor
runtime
diagnostics
detected
memory
DIMM
fault
Memory
DIMM
16,
riser
2
Location:
U1.1-P1-M2.16
4067
0535
6xx
bus
processor
runtime
diagnostics
detected
memory
DIMM
fault
Memory
DIMM
23,
riser
2
Location:
U1.1-P1-M2.23
4067
0536
6xx
bus
processor
runtime
diagnostics
detected
memory
DIMM
fault
Memory
DIMM
24,
riser
2
Location:
U1.1-P1-M2.24
4067
0537
6xx
bus
processor
runtime
diagnostics
detected
memory
DIMM
fault
Memory
DIMM
31,
riser
2
Location:
U1.1-P1-M2.31
4067
0538
6xx
bus
processor
runtime
diagnostics
detected
memory
DIMM
fault
Memory
DIMM
32,
riser
2
Location:
U1.1-P1-M2.32
4067
053D
6xx
bus
processor
runtime
diagnostics
detected
memory
DIMM
group
fault
Memory
octal
D,
riser
2
Location:
U1.1-P1-M2.7
x8
4067
053E
6xx
bus
processor
runtime
diagnostics
detected
memory
DIMM
group
fault
Memory
quad
D
odd,
riser
2
Location:
U1.1-P1-M2.7
x4
4067
053F
6xx
bus
processor
runtime
diagnostics
detected
memory
DIMM
group
fault
Memory
quad
D
even,
riser
2
Location:
U1.1-P1-M2.8
x4
4067
05FF
6xx
bus
processor
runtime
diagnostics
detected
memory
on
riser
fault
Memory
failure
on
riser
card
2
that
cannot
be
automatically
isolated.
go
to
“MAP
1540:
Minimum
Configuration”
on
page
110
and
run
CEC
drawer
minimum
configuration
for
further
isolation.
4067
0600
6xx
bus
processor
runtime
diagnostics
detected
CEC
RIO
bus
adapter
CEC
RIO
bus
adapter
Location:
U1.1-P1.1
220
Service
Guide
Содержание RS/6000 Enterprise Server M80
Страница 1: ...RS 6000 Enterprise Server Model M80 Eserver pSeries 660 Model 6M1 Service Guide SA38 0571 01...
Страница 10: ...x Service Guide...
Страница 14: ...xiv Service Guide...
Страница 16: ...xvi Service Guide...
Страница 22: ...Data Flow 4 Service Guide...
Страница 28: ...CEC Drawer Front View With Bezel Removed 3 2 1 1 Power On Off LED 2 Fan 2 3 Fan 1 10 Service Guide...
Страница 30: ...CEC Card Cage Rear of CEC drawer viewed from top cover removed 12 Service Guide...
Страница 84: ...66 Service Guide...
Страница 176: ...158 Service Guide...
Страница 376: ...358 Service Guide...
Страница 430: ...412 Service Guide...
Страница 445: ...3 Insert the memory module firmly into the connector Chapter 10 Removal and Replacement Procedures 427...
Страница 476: ...7 Remove the screws that connect the carrier to the CD ROM Replacement Replace in reverse order 458 Service Guide...
Страница 485: ...Chapter 11 Parts Information This chapter contains parts information for the system 467...
Страница 486: ...CEC Drawer Card Assembly 9 468 Service Guide...
Страница 488: ...CEC Drawer Backplane 5 2a 1 2 3 4 470 Service Guide...
Страница 490: ...CEC Drawer Power Supplies 1 2 3 4 5 6 7 8 9 472 Service Guide...
Страница 492: ...CEC Drawer Fan Assemblies 2 1 3 4 5 6 8 9 10 11 12 13 7 14 474 Service Guide...
Страница 494: ...I O Drawer 1 2 3 4 5 6 7 8 9 10 11 16 17 18 19 20 12 14 13 13 15 21 22 23 24 26 25 27 476 Service Guide...
Страница 496: ...7 8 9 10 6 1 2 3 4 4 5 478 Service Guide...
Страница 508: ...490 Service Guide...
Страница 520: ...502 Service Guide...
Страница 522: ...504 Service Guide...
Страница 526: ...508 Service Guide...
Страница 542: ...error Handle unexpected modem responses expect 8 r or 7 r or 6 r or 4 r or 3 r delay 2 done 524 Service Guide...
Страница 558: ...540 Service Guide...
Страница 565: ......
Страница 566: ...Printed in USA September 2001 SA38 0571 01...
Страница 567: ...Spine information RS 6000 Enterprise Server Model M80 Eserver pSeries 660 Model 6M1 Service Guide SA38 0571 01...