![IBM RS/6000 Enterprise Server M80 Скачать руководство пользователя страница 279](http://html1.mh-extra.com/html/ibm/rs-6000-enterprise-server-m80/rs-6000-enterprise-server-m80_service-manual_4215775279.webp)
Table
7.
Service
Processor
Error
Codes
(continued)
Error
Code
Description
Action/
Possible
Failing
FRU
406E
00A2
Scan
control
routines
detected
service
processor
firmware
(processor
runtime
diagnostics)
fault
Check
for
system
firmware
updates
Location:
U0.1-P1/Y1
406E
00A3
Scan
control
routines
detected
memory
plugging
fault
All
pluggable
memory
406E
00A4
Scan
control
routines
detected
application
caused
fault
Application
software
406E
00A5
Scan
control
routines
detected
invalid
system
configuration
Verify
system
components
are
supported
and
properly
installed.
406E
00A6
Scan
control
routines
detected
no
usable
memory
1.
Ensure
that
CEC
memory
is
properly
installed.
2.
If
more
than
one
DIMM
is
called
out,
go
to
the
service
processor
Memory
Configuration/Deconfiguration
Menu
to
verify
memory
DIMMs
state.
See
″
Memory
Configuration/Deconfiguration
Menu
″
on
page
374
for
more
information.
406E
00A7
Scan
control
routines
detected
hardware
problem
Go
to
minimum
configuration
and
also
run
CEC
minimum
configuration
406E
00B0
Scan
control
routines
detected
bus
controller
lock-unlock
failure
RIO
bus
adapter
Location:
U0.1-P1.1
406E
00B1
Scan
control
routines
detected
bus
controller
failure
RIO
bus
adapter
Location:
U0.1-P1.1
406E
00B3
Scan
control
routines
detected
clock
fault
1.
Clock
card
Location:
U1.1-P1.1.1
2.
CEC
RIO
bus
adapter
Location:
U1.1-P1.1
406E
00B7
Scan
control
routines
detected
insufficient
hardware
resources
to
continue
IPL
This
error
code
appears
after
the
initial
testing
by
the
service
processor
firmware
on
the
CEC
was
completed
correctly,
but
a
problem
occurred
when
the
firmware
tried
to
communicate
outside
the
CEC.
Suspect
a
problem
with
the
RIO
interface,
either
cables
or
adapters.
406E
0200
Scan
control
routines
detected
memory
riser
card
fault
Memory
riser
card
1
Location:
U1.1-P1-M1
406E
0201
Scan
control
routines
detected
memory
DIMM
fault
Memory
DIMM
1,
riser
1
Location:
U1.1-P1-M1.1
406E
0202
Scan
control
routines
detected
memory
DIMM
fault
Memory
DIMM
2,
riser
1
Location:
U1.1-P1-M1.2
406E
0203
Scan
control
routines
detected
memory
DIMM
fault
Memory
DIMM
9,
riser
1
Location:
U1.1-P1-M1.9
406E
0204
Scan
control
routines
detected
memory
DIMM
fault
Memory
DIMM
10,
riser
1
Location:
U1.1-P1-M1.10
406E
0205
Scan
control
routines
detected
memory
DIMM
fault
Memory
DIMM
17,
riser
1
Location:
U1.1-P1-M1.17
406E
0206
Scan
control
routines
detected
memory
DIMM
fault
Memory
DIMM
18,
riser
1
Location:
U1.1-P1-M1.18
Chapter
5.
Error
Code
to
FRU
Index
261
Содержание RS/6000 Enterprise Server M80
Страница 1: ...RS 6000 Enterprise Server Model M80 Eserver pSeries 660 Model 6M1 Service Guide SA38 0571 01...
Страница 10: ...x Service Guide...
Страница 14: ...xiv Service Guide...
Страница 16: ...xvi Service Guide...
Страница 22: ...Data Flow 4 Service Guide...
Страница 28: ...CEC Drawer Front View With Bezel Removed 3 2 1 1 Power On Off LED 2 Fan 2 3 Fan 1 10 Service Guide...
Страница 30: ...CEC Card Cage Rear of CEC drawer viewed from top cover removed 12 Service Guide...
Страница 84: ...66 Service Guide...
Страница 176: ...158 Service Guide...
Страница 376: ...358 Service Guide...
Страница 430: ...412 Service Guide...
Страница 445: ...3 Insert the memory module firmly into the connector Chapter 10 Removal and Replacement Procedures 427...
Страница 476: ...7 Remove the screws that connect the carrier to the CD ROM Replacement Replace in reverse order 458 Service Guide...
Страница 485: ...Chapter 11 Parts Information This chapter contains parts information for the system 467...
Страница 486: ...CEC Drawer Card Assembly 9 468 Service Guide...
Страница 488: ...CEC Drawer Backplane 5 2a 1 2 3 4 470 Service Guide...
Страница 490: ...CEC Drawer Power Supplies 1 2 3 4 5 6 7 8 9 472 Service Guide...
Страница 492: ...CEC Drawer Fan Assemblies 2 1 3 4 5 6 8 9 10 11 12 13 7 14 474 Service Guide...
Страница 494: ...I O Drawer 1 2 3 4 5 6 7 8 9 10 11 16 17 18 19 20 12 14 13 13 15 21 22 23 24 26 25 27 476 Service Guide...
Страница 496: ...7 8 9 10 6 1 2 3 4 4 5 478 Service Guide...
Страница 508: ...490 Service Guide...
Страница 520: ...502 Service Guide...
Страница 522: ...504 Service Guide...
Страница 526: ...508 Service Guide...
Страница 542: ...error Handle unexpected modem responses expect 8 r or 7 r or 6 r or 4 r or 3 r delay 2 done 524 Service Guide...
Страница 558: ...540 Service Guide...
Страница 565: ......
Страница 566: ...Printed in USA September 2001 SA38 0571 01...
Страница 567: ...Spine information RS 6000 Enterprise Server Model M80 Eserver pSeries 660 Model 6M1 Service Guide SA38 0571 01...