Table
2.
Firmware
Checkpoints
(continued)
Checkpoint
Description
Action/
Possible
Failing
FRU
E5xy
(E511
-
E5FF)
Where
x
is
not
equal
to
0,
and
y
is
not
equal
to
0.
Configure
remote
I/O
subsystem
components
The
E5xy
(E511
to
E5FF)
codes
are
reserved
for
activities
relating
to
configuration
or
testing
of
the
I/O
subsystem,
or
remote
I/O
subsystem.
A
hang
at
one
of
these
codes
implies
that
a
severe
error
occurred
during
the
programming
of
I/O
subsystem
registers
or
when
interacting
with
adapters
plugged
into
the
system.
The
last
two
digits
in
the
checkpoint
can
be
used
to
help
isolate
the
location
of
the
I/O
activity
that
caused
the
problem.
“
x
”
indicates
the
I/O
drawer
number.
“
y
”
indicates
the
PCI
bus
occurrence.
If
y
=_,
then
the
PCI
bus
is:
Y
=
PCI
bus
1
=
0
2
=
1
3
=
2
4
=
3
See
“AIX
and
Physical
Location
Code
Tables”
in
Chapter
1,
for
location
codes.
Using
the
information
above,
go
to
“MAP
1540:
Minimum
Configuration”
on
page
110.
E600
SSA
PCI
adapter
open
firmware
has
run
successfully.
Replace
the
adapter.
See
“Determining
Location
Code”
on
page
160
for
location
code
information
related
to
this
error.
E601
SSA
PCI
adapter
BIST
has
started
but
failed
to
complete
after
four
seconds.
Replace
the
adapter.
See
“Determining
Location
Code”
on
page
160
for
location
code
information
related
to
this
error.
E602
SSA
PCI
adapter
open
firmware
has
started.
Replace
the
adapter.
See
“Determining
Location
Code”
on
page
160
for
location
code
information
related
to
this
error.
E603
SSA
PCI
adapter
BIST
has
completed
with
an
error.
Replace
the
adapter.
See
“Determining
Location
Code”
on
page
160
for
location
code
information
related
to
this
error.
Chapter
4.
Checkpoints
153
Содержание RS/6000 Enterprise Server M80
Страница 1: ...RS 6000 Enterprise Server Model M80 Eserver pSeries 660 Model 6M1 Service Guide SA38 0571 01...
Страница 10: ...x Service Guide...
Страница 14: ...xiv Service Guide...
Страница 16: ...xvi Service Guide...
Страница 22: ...Data Flow 4 Service Guide...
Страница 28: ...CEC Drawer Front View With Bezel Removed 3 2 1 1 Power On Off LED 2 Fan 2 3 Fan 1 10 Service Guide...
Страница 30: ...CEC Card Cage Rear of CEC drawer viewed from top cover removed 12 Service Guide...
Страница 84: ...66 Service Guide...
Страница 176: ...158 Service Guide...
Страница 376: ...358 Service Guide...
Страница 430: ...412 Service Guide...
Страница 445: ...3 Insert the memory module firmly into the connector Chapter 10 Removal and Replacement Procedures 427...
Страница 476: ...7 Remove the screws that connect the carrier to the CD ROM Replacement Replace in reverse order 458 Service Guide...
Страница 485: ...Chapter 11 Parts Information This chapter contains parts information for the system 467...
Страница 486: ...CEC Drawer Card Assembly 9 468 Service Guide...
Страница 488: ...CEC Drawer Backplane 5 2a 1 2 3 4 470 Service Guide...
Страница 490: ...CEC Drawer Power Supplies 1 2 3 4 5 6 7 8 9 472 Service Guide...
Страница 492: ...CEC Drawer Fan Assemblies 2 1 3 4 5 6 8 9 10 11 12 13 7 14 474 Service Guide...
Страница 494: ...I O Drawer 1 2 3 4 5 6 7 8 9 10 11 16 17 18 19 20 12 14 13 13 15 21 22 23 24 26 25 27 476 Service Guide...
Страница 496: ...7 8 9 10 6 1 2 3 4 4 5 478 Service Guide...
Страница 508: ...490 Service Guide...
Страница 520: ...502 Service Guide...
Страница 522: ...504 Service Guide...
Страница 526: ...508 Service Guide...
Страница 542: ...error Handle unexpected modem responses expect 8 r or 7 r or 6 r or 4 r or 3 r delay 2 done 524 Service Guide...
Страница 558: ...540 Service Guide...
Страница 565: ......
Страница 566: ...Printed in USA September 2001 SA38 0571 01...
Страница 567: ...Spine information RS 6000 Enterprise Server Model M80 Eserver pSeries 660 Model 6M1 Service Guide SA38 0571 01...