Table
7.
Service
Processor
Error
Codes
(continued)
Error
Code
Description
Action/
Possible
Failing
FRU
4067
0206
6xx
bus
processor
runtime
diagnostics
detected
memory
DIMM
fault
Memory
DIMM
18,
riser
1
Location:
U1.1-P1-M1.18
4067
0207
6xx
bus
processor
runtime
diagnostics
detected
memory
DIMM
fault
Memory
DIMM
25,
riser
1
Location:
U1.1-P1-M1.25
4067
0208
6xx
bus
processor
runtime
diagnostics
detected
memory
DIMM
fault
Memory
DIMM
26,
riser
1
Location:
U1.1-P1-M1.26
4067
020D
6xx
bus
processor
runtime
diagnostics
detected
memory
DIMM
group
fault
Memory
octal
A,
riser
1
Location:
U1.1-P1-M1.1
x8
4067
020E
6xx
bus
processor
runtime
diagnostics
detected
memory
DIMM
group
fault
Memory
quad
A
odd,
riser
1
Locations:
U1.1-P1-M1.1
x4
4067
020F
6xx
bus
processor
runtime
diagnostics
detected
memory
DIMM
group
fault
Memory
quad
A
even,
riser
1
Locations:
U1.1-P1-M1.2
x4
4067
0211
6xx
bus
processor
runtime
diagnostics
detected
memory
DIMM
fault
Memory
DIMM
3,
riser
1
Location:
U1.1-P1-M1.3
4067
0212
6xx
bus
processor
runtime
diagnostics
detected
memory
DIMM
fault
Memory
DIMM
4,
riser
1
Location:
U1.1-P1-M1.4
4067
0213
6xx
bus
processor
runtime
diagnostics
detected
memory
DIMM
fault
Memory
DIMM
11,
riser
1
Location:
U1.1-P1-M1.11
4067
0214
6xx
bus
processor
runtime
diagnostics
detected
memory
DIMM
fault
Memory
DIMM
12,
riser
1
Location:
U1.1-P1-M1.12
4067
0215
6xx
bus
processor
runtime
diagnostics
detected
memory
DIMM
fault
Memory
DIMM
19,
riser
1
Location:
U1.1-P1-M1.19
4067
0216
6xx
bus
processor
runtime
diagnostics
detected
memory
DIMM
fault
Memory
DIMM
20,
riser
1
Location:
U1.1-P1-M1.20
4067
0217
6xx
bus
processor
runtime
diagnostics
detected
memory
DIMM
fault
Memory
DIMM
27,
riser
1
Location:
U1.1-P1-M1.27
4067
0218
6xx
bus
processor
runtime
diagnostics
detected
memory
DIMM
fault
Memory
DIMM
28,
riser
1
Location:
U1.1-P1-M1.28
4067
021D
6xx
bus
processor
runtime
diagnostics
detected
memory
DIMM
group
fault
Memory
octal
B,
riser
1
Location:
U1.1-P1-M1.3
x8
4067
021E
6xx
bus
processor
runtime
diagnostics
detected
memory
DIMM
group
pair
A
fault
Memory
quad
B
odd,
riser
1
Location:
U1.1-P1-M1.3
x4
4067
021F
6xx
bus
processor
runtime
diagnostics
detected
memory
DIMM
group
fault
Memory
quad
B
even,
riser
1
Location:
U1.1-P1-M1.4
x4
4067
0221
6xx
bus
processor
runtime
diagnostics
detected
memory
DIMM
fault
Memory
DIMM
5,
riser
1
Location:
U1.1-P1-M1.5
4067
0222
6xx
bus
processor
runtime
diagnostics
detected
memory
DIMM
fault
Memory
DIMM
6,
riser
1
Location:
U1.1-P1-M1.6
4067
0223
6xx
bus
processor
runtime
diagnostics
detected
memory
DIMM
fault
Memory
DIMM
13,
riser
1
Location:
U1.1-P1-M1.13
4067
0224
6xx
bus
processor
runtime
diagnostics
detected
memory
DIMM
fault
Memory
DIMM
14,
riser
1
Location:
U1.1-P1-M1.14
4067
0225
6xx
bus
processor
runtime
diagnostics
detected
memory
DIMM
fault
Memory
DIMM
21,
riser
1
Location:
U1.1-P1-M1.21
4067
0226
6xx
bus
processor
runtime
diagnostics
detected
memory
DIMM
fault
Memory
DIMM
22,
riser
1
Location:
U1.1-P1-M1.22
Chapter
5.
Error
Code
to
FRU
Index
217
Содержание RS/6000 Enterprise Server M80
Страница 1: ...RS 6000 Enterprise Server Model M80 Eserver pSeries 660 Model 6M1 Service Guide SA38 0571 01...
Страница 10: ...x Service Guide...
Страница 14: ...xiv Service Guide...
Страница 16: ...xvi Service Guide...
Страница 22: ...Data Flow 4 Service Guide...
Страница 28: ...CEC Drawer Front View With Bezel Removed 3 2 1 1 Power On Off LED 2 Fan 2 3 Fan 1 10 Service Guide...
Страница 30: ...CEC Card Cage Rear of CEC drawer viewed from top cover removed 12 Service Guide...
Страница 84: ...66 Service Guide...
Страница 176: ...158 Service Guide...
Страница 376: ...358 Service Guide...
Страница 430: ...412 Service Guide...
Страница 445: ...3 Insert the memory module firmly into the connector Chapter 10 Removal and Replacement Procedures 427...
Страница 476: ...7 Remove the screws that connect the carrier to the CD ROM Replacement Replace in reverse order 458 Service Guide...
Страница 485: ...Chapter 11 Parts Information This chapter contains parts information for the system 467...
Страница 486: ...CEC Drawer Card Assembly 9 468 Service Guide...
Страница 488: ...CEC Drawer Backplane 5 2a 1 2 3 4 470 Service Guide...
Страница 490: ...CEC Drawer Power Supplies 1 2 3 4 5 6 7 8 9 472 Service Guide...
Страница 492: ...CEC Drawer Fan Assemblies 2 1 3 4 5 6 8 9 10 11 12 13 7 14 474 Service Guide...
Страница 494: ...I O Drawer 1 2 3 4 5 6 7 8 9 10 11 16 17 18 19 20 12 14 13 13 15 21 22 23 24 26 25 27 476 Service Guide...
Страница 496: ...7 8 9 10 6 1 2 3 4 4 5 478 Service Guide...
Страница 508: ...490 Service Guide...
Страница 520: ...502 Service Guide...
Страница 522: ...504 Service Guide...
Страница 526: ...508 Service Guide...
Страница 542: ...error Handle unexpected modem responses expect 8 r or 7 r or 6 r or 4 r or 3 r delay 2 done 524 Service Guide...
Страница 558: ...540 Service Guide...
Страница 565: ......
Страница 566: ...Printed in USA September 2001 SA38 0571 01...
Страница 567: ...Spine information RS 6000 Enterprise Server Model M80 Eserver pSeries 660 Model 6M1 Service Guide SA38 0571 01...