FRU
Name
Location
Code
AIX
Location
Code
Physical
Connection
Logical
Connection
PCI
slot
2
U0.3-P1/I2
90-5A
PCI
slot
2
content
(card)
U0.3-P1-I2
94-08
through
94-0F
or
95-xx
or
96-xx
PCI
slot
3
U0.3-P1/I3
90-5C
PCI
slot
3
content
(card)
U0.3-P1-I3
97-08
through
97-0F
or
98-xx
or
99-xx
PCI
slot
4
U0.3-P1/I4
90-5E
PCI
slot
4
content
(card)
U0.3-P1-I4
9A-08
through
9A-0F
or
9B-xx
or
9C-xx
PCI
to
PCI
bridge
2
U0.3-P1
A0-58,
A0-5A,
A0-5B,
A0-5C,
A0-5E
PCI
slot
5
U0.3-P1/I5
A0-58
PCI
slot
5
content
(card)
U0.3-P1-I5
A1-08
through
A1-0F
or
A2-xx
or
A3-xx
PCI
slot
6
(5V)
U0.3-P1/I6
A0-5A
PCI
slot
6
content
(card)
U0.3-P1-I6
A4-08
through
A4-0F
or
A5-xx
or
A6-xx
PCI
slot
7
(5V)
U0.3-P1/I7
A0-5B
PCI
slot
7
content
(card)
A0.3-P1-I7
A7-08
through
A7-0F
or
A8-xx
or
A9-xx
PCI
slot
8
A0.3-P1/I8
A0-5C
PCI
slot
8
content
(card)
U0.3-P1-I8
AA-08
through
AA-0F
or
AB-xx
or
AC-xx
PCI
slot
9
U0.3-P1/I9
A0-5E
PCI
slot
9
content
(card)
U0.3-P1-I9
AD-08
through
AD-0F
or
AE-xx
or
AF-xx
PCI
to
PCI
bridge
3
U0.3-P1
A0-60,
A0-62,
A0-63,
A0-64,
A0-66
PCI
slot
10
U0.3-P1/I10
A0-60
PCI
slot
10
content
(card)
U0.3-P1-I10
B1-08
through
B1-0F
or
B2-xx
or
B3-xx
PCI
slot
11
(5V)
U0.3-P1/I11
A0-62
PCI
slot
11
content
(card)
U0.3-P1-I11
B4-08
through
B4-0F
or
B5-xx
or
B6-xx
PCI
slot
12
(5V)
U0.3-P1/I12
A0-63
PCI
slot
12
content
(card)
U0.3-P1-I12
B7-08
through
B7-0F
or
B8-xx
or
B9-xx
PCI
slot
13
U0.3-P1/I13
A0-64
PCI
slot
13
content
(card)
U0.3-P1-I13
BA-08
through
BA-0F
or
BB-xx
or
BC-xx
PCI
slot
14
U0.3-P1/I14
A0-66
Chapter
1.
Reference
Information
41
Содержание RS/6000 Enterprise Server M80
Страница 1: ...RS 6000 Enterprise Server Model M80 Eserver pSeries 660 Model 6M1 Service Guide SA38 0571 01...
Страница 10: ...x Service Guide...
Страница 14: ...xiv Service Guide...
Страница 16: ...xvi Service Guide...
Страница 22: ...Data Flow 4 Service Guide...
Страница 28: ...CEC Drawer Front View With Bezel Removed 3 2 1 1 Power On Off LED 2 Fan 2 3 Fan 1 10 Service Guide...
Страница 30: ...CEC Card Cage Rear of CEC drawer viewed from top cover removed 12 Service Guide...
Страница 84: ...66 Service Guide...
Страница 176: ...158 Service Guide...
Страница 376: ...358 Service Guide...
Страница 430: ...412 Service Guide...
Страница 445: ...3 Insert the memory module firmly into the connector Chapter 10 Removal and Replacement Procedures 427...
Страница 476: ...7 Remove the screws that connect the carrier to the CD ROM Replacement Replace in reverse order 458 Service Guide...
Страница 485: ...Chapter 11 Parts Information This chapter contains parts information for the system 467...
Страница 486: ...CEC Drawer Card Assembly 9 468 Service Guide...
Страница 488: ...CEC Drawer Backplane 5 2a 1 2 3 4 470 Service Guide...
Страница 490: ...CEC Drawer Power Supplies 1 2 3 4 5 6 7 8 9 472 Service Guide...
Страница 492: ...CEC Drawer Fan Assemblies 2 1 3 4 5 6 8 9 10 11 12 13 7 14 474 Service Guide...
Страница 494: ...I O Drawer 1 2 3 4 5 6 7 8 9 10 11 16 17 18 19 20 12 14 13 13 15 21 22 23 24 26 25 27 476 Service Guide...
Страница 496: ...7 8 9 10 6 1 2 3 4 4 5 478 Service Guide...
Страница 508: ...490 Service Guide...
Страница 520: ...502 Service Guide...
Страница 522: ...504 Service Guide...
Страница 526: ...508 Service Guide...
Страница 542: ...error Handle unexpected modem responses expect 8 r or 7 r or 6 r or 4 r or 3 r delay 2 done 524 Service Guide...
Страница 558: ...540 Service Guide...
Страница 565: ......
Страница 566: ...Printed in USA September 2001 SA38 0571 01...
Страница 567: ...Spine information RS 6000 Enterprise Server Model M80 Eserver pSeries 660 Model 6M1 Service Guide SA38 0571 01...