as
available
for
future
capacity
and
the
failed
processors
marked
as
failed.
The
customer
can
continue
to
run
the
system
without
degradation.
However,
in
such
a
case,
the
failing
processor
card
should
be
replaced
at
the
customer’s
convenience
to
allow
the
customer
to
add
capacity
as
needed.
Use
the
chcod
command
to
manage
Capacity
Upgrade
on
Demand
resources.
It
is
also
used
to
determine
the
number
of
resources
that
are
authorized
and
the
total
number
of
resources
installed.
Testing
the
System
in
the
Capacity
Upgrade
on
Demand
Environment
To
test
all
the
processors
installed
in
a
machine
that
has
a
Capacity
Upgrade
on
Demand
feature
installed,
do
the
following:
1.
Log
in
to
the
system
as
root
user
or
as
a
user
with
system
group
privileges.
2.
To
determine
if
Capacity
Upgrade
on
Demand
is
currently
enabled,
type
the
following
command:
chcod
Record
the
displayed
information
below:
Current
MailAddress
_______Reserved________
Current
CustInfo
_______________________
Current
Model
and
System
ID
=
IBM,
xxxx-______IBM,
________
Current
number
of
authorized
proc(s)
out
of
(xx_____)
installed
on
system
=
(yy_____)
where
(xx)
is
the
number
processors
installed
in
the
system,
(yy)
is
the
number
of
Capacity
Upgrade
on
Demand-enabled
processors.
If
(yy)
is
equal
to
0,
then
Capacity
Upgrade
on
Demand
is
not
enabled.
If
(yy)
is
greater
than
0,
then
Capacity
Upgrade
on
Demand
is
enabled.
3.
To
enable
testing
of
all
the
installed
processors,
disable
Capacity
Upgrade
on
Demand
by
setting
the
number
_of
_
processors
(yy)
equal
to
0:
chcod
-r
proc
-n
0
4.
Shut
down
and
reboot
the
system,
as
follows:
shutdown
-Fr
5.
To
verify
the
installed
processors,
type
the
following
at
the
command
line:
bindprocessor
-q
Information
about
installed
processor
boards
displays.
v
If
two
processor
boards
are
installed,
the
available
processors
should
be
listed
as
0
to
7.
v
If
the
number
of
installed
processors
is
not
correct,
use
the
normal
maintenance
package
procedures
to
correct
any
problems.
6.
To
test
the
system,
type
the
following
at
the
command
line:
diag
7.
Select
Advanced
Diagnostics
.
8.
Select
System
Verification
mode
on
sysplanar0
and
all
processors.
Use
the
normal
maintenance
package
procedures
to
correct
any
problems.
9.
When
the
system
is
ready
to
return
to
normal
operations,
reset
the
Capacity
Upgrade
on
Demand
feature,
as
follows:
a.
Log
in
to
the
system
as
root
user
or
as
a
user
with
system
group
privileges.
b.
Type
the
following
at
the
command
line:
chcod
-r
proc
-n
NbrResources
where
NbrResources
is
equal
to
the
value
of
(yy)
recorded
in
step
2.
506
Service
Guide
Содержание RS/6000 Enterprise Server M80
Страница 1: ...RS 6000 Enterprise Server Model M80 Eserver pSeries 660 Model 6M1 Service Guide SA38 0571 01...
Страница 10: ...x Service Guide...
Страница 14: ...xiv Service Guide...
Страница 16: ...xvi Service Guide...
Страница 22: ...Data Flow 4 Service Guide...
Страница 28: ...CEC Drawer Front View With Bezel Removed 3 2 1 1 Power On Off LED 2 Fan 2 3 Fan 1 10 Service Guide...
Страница 30: ...CEC Card Cage Rear of CEC drawer viewed from top cover removed 12 Service Guide...
Страница 84: ...66 Service Guide...
Страница 176: ...158 Service Guide...
Страница 376: ...358 Service Guide...
Страница 430: ...412 Service Guide...
Страница 445: ...3 Insert the memory module firmly into the connector Chapter 10 Removal and Replacement Procedures 427...
Страница 476: ...7 Remove the screws that connect the carrier to the CD ROM Replacement Replace in reverse order 458 Service Guide...
Страница 485: ...Chapter 11 Parts Information This chapter contains parts information for the system 467...
Страница 486: ...CEC Drawer Card Assembly 9 468 Service Guide...
Страница 488: ...CEC Drawer Backplane 5 2a 1 2 3 4 470 Service Guide...
Страница 490: ...CEC Drawer Power Supplies 1 2 3 4 5 6 7 8 9 472 Service Guide...
Страница 492: ...CEC Drawer Fan Assemblies 2 1 3 4 5 6 8 9 10 11 12 13 7 14 474 Service Guide...
Страница 494: ...I O Drawer 1 2 3 4 5 6 7 8 9 10 11 16 17 18 19 20 12 14 13 13 15 21 22 23 24 26 25 27 476 Service Guide...
Страница 496: ...7 8 9 10 6 1 2 3 4 4 5 478 Service Guide...
Страница 508: ...490 Service Guide...
Страница 520: ...502 Service Guide...
Страница 522: ...504 Service Guide...
Страница 526: ...508 Service Guide...
Страница 542: ...error Handle unexpected modem responses expect 8 r or 7 r or 6 r or 4 r or 3 r delay 2 done 524 Service Guide...
Страница 558: ...540 Service Guide...
Страница 565: ......
Страница 566: ...Printed in USA September 2001 SA38 0571 01...
Страница 567: ...Spine information RS 6000 Enterprise Server Model M80 Eserver pSeries 660 Model 6M1 Service Guide SA38 0571 01...